【摘 要】
:
With the great development of laser standard systems and high-precision laser measurement systems, demands of optical systems have resulted in a dramatic increase in performance requirements for thin film optical filters. In this letter, the analysis and
【机 构】
:
InstituteofPrecisionOpticalEngineering,TongjiUniversity,Shanghai200192,ChinaTianjinKeyLaboratoryofOp
【出 处】
:
ChineseOpticsLetters
论文部分内容阅读
With the great development of laser standard systems and high-precision laser measurement systems, demands of optical systems have resulted in a dramatic increase in performance requirements for thin film optical filters. In this letter, the analysis and manufacture of the double-layer structure of the ultra-low residual reflectance for a single wavelength are reviewed. From a manufacturing standpoint, the manufacture and analysis of these coatings, which satisfy the requirements mentioned, pose as major problems. The coatings are characterized according to ellipsometry analyses and adjustment of the center wavelength of the antireflection (AR) coating Ta2O5/SiO2 double layers. AR coating is deposited on silica substrates by ion beam sputtering (IBS) technique, thus, achieving residual reflectance of less than 0.005% at \lambda 0=632.8 nm.
其他文献
利用锁相热像方法定量测量了光学镀膜的吸收率。待测薄膜吸收周期调制的激光能量,在表面形成热波,将红外相机记录的热分布信号进行锁相相关处理,获得信噪比提高的热图像。采用标准吸收样品对系统进行定标,可获得光热信号幅度与样品吸收率之间的定量联系,进而在相同实验条件下测量待测样品,可通过光热信号直接计算获得其绝对吸收率。在1 060 nm波长处开展了实验研究,测量获得了不同厚度Nb2O5镀膜的吸收率数值,实测的吸收可达80 ppm。
以O3在8.823 μm波段的辐射为探测源,通过干涉仪获取其精细光谱的多普勒频移反演,是平流层风场探测的重要途径。鉴于此,通过对O3临边辐射光谱特性进行分析,确定了最佳的目标谱线;利用三级红外Fabry-Perot标准具联合滤光,实现了目标谱线的提取;通过建立Michelson干涉仪数值模型,得到了临边观测情况下白天及夜间工作时的四步进干涉图像;通过误差分析,论证了15~45 km范围内,白天及晚上的视向风测量误差均在1~2 m/s范围内。因此,以O3
针对星相机在轨因卫星运动和曝光时间设定的动态条件引起的星点模糊导致星点提取精度下降的问题, 提出一种动态星点坐标确定误差补偿方法, 利用在星相机光学系统入瞳前加入阶梯玻璃的手段实现了提高星相机摄星指向精度的目的。地面标定和在轨测试表明, 星相机指向精度优于1″, 验证了该方法的有效性, 具有一定的应用价值。
Microendoscopes are vital for disease detection and clinical diagnosis. The essential issue for microendoscopes is to achieve minimally invasive and high-resolution observations of soft tissue structures inside deep body cavities. Obviously, the microscop
A reflecting ring focusing system for laser propulsion has been designed. A paraboloidal reflector of higher order is constructed to focus the laser energy on a ring which can produce a tire liked ignition region in the thruster. Considering the angle of
在全光网络中光码流的性能监控、强场物理中单次激光脉冲性能评估、干涉测速以及其他许多物理过程中都需要对瞬态光信号进行实时测量。提出了一种结合宽光谱抽运四波混频光-光采样和时间拉伸的瞬态光信号实时测量技术,拟利用特种光纤的超快非线性效应对光信号进行超分辨率采样,同时将单波长信号转换为宽光谱信号,进而利用光纤色散傅里叶变换对信号进行时间拉伸,可大为降低初始光信号带宽。对宽光谱四波混频和时间拉伸过程进行了理论分析,表明该方案是完全可行的。
微纳光波导的基本功能是实现光波的低损耗传输, 是芯片光互连的基础, 其传输损耗是评价微纳光波导加工质量和传输性能的基本指标。微纳光波导由于其尺寸比常规光波导小1~2个数量级, 光耦合的难度和不确定性都很大, 造成传输损耗的测量相对困难。探讨了可用于微纳光波导传输损耗测试表征的几种方法, 包括截断法、法布里-珀罗(Fabry-Pérot,F-P)腔谐振谱条纹对比度分析法、傅里叶(Fourier)变换法等, 对上述方法在测试精度、适用条件方面进行了分析对比。研究表明, 截断法受光纤耦合不确定性的影响测量误差较
提出了一种新颖的光纤液位传感器。在普通单模光纤(SMF)中间熔接一段细芯单模光纤(TCSMF),构成共轴光纤马赫曾德尔干涉仪(MZI)。液位的变化引起包层模与芯模的相位差发生改变,从而导致干涉仪的透射光谱发生改变。对传感器的工作原理和测量灵敏度及精度进行了理论分析,实验结果显示透射光谱中特征峰波长漂移量跟液位变化量呈较好的线性关系,且灵敏度随待测液体折射率的增大而增高,与理论分析结果相一致。测量得到纯水和饱和氯化钠溶液的测量灵敏度分别为0.160 nm/mm和0.228 nm/mm。该传感器采用全光纤结构
空气间隔偏振棱镜的气隙厚度可无穷减小,以获得大的半视场角,但其消光比将受到严重影响。本文给出获得高消光比的条件。