【摘 要】
:
Thermal analysis of data centers is in urgent need to ensure that computer chips remain below the critical temperature while the energy consumption for cooling can be reduced.It is difficult to obtain detailed hotspot locations and temperatures of chips i
【机 构】
:
Key Laboratory of Thermo-Fluid Science and Engineering of MOE,School of Energy and Power Engineering
论文部分内容阅读
Thermal analysis of data centers is in urgent need to ensure that computer chips remain below the critical temperature while the energy consumption for cooling can be reduced.It is difficult to obtain detailed hotspot locations and temperatures of chips in large data centers containing hundreds of racks or more by direct measurement.In this paper,a multi-scale thermal analysis method is proposed that can predict the temperature distribution of chips and solder balls in data centers.The multi-scale model is divided into six scales:room,rack,server,Insulated-Gate Bipolar Transistor(IGBT),chip and solder ball.A concept of sub-model is proposed and the six levels are organized into four simulation sub-models.Sub-model 1 contains Room,Rack and Server(RRS);Sub-model 2 contains Server and IGBT(SI);Sub-model 3 contains IGBT and Chip(IC),and Sub-model 4 contains Chip and Solder-ball(CS).These four sub-models are one-way coupled by transmitting their results as boundary conditions between levels.The full-field simulation method is employed to verify the efficiency and accuracy of multi-scale simulation method for a single-rack data center.The two simulation results show that the highest temperature emerges in the same location.The Single-rack Full-field Model(SRFFM)costs 2.5 times more computational time than that with Single-rack Multi-scale Model(SRMSM).The deviation of the highest temperature of chips and solder balls are 1.57℃and 0.2℃between the two models which indicates that the multi-scale simulation method has good prospect in the data center thermal simulation.Finally,the multi-scale thermal analysis method is applied to a ship data center with 15 racks.
其他文献
The cooling performance of air-cooled condenser(ACC)is susceptible to adverse impacts of ambient winds.In this work,three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to weaken the unfavorable effects of cross w
Ldha基因表达可生成参与糖代谢的乳酸脱氢酶(LDH),通过克隆黄胸鼠Rattus tanezumi的Ldha基因并进行原核表达后可以研究其酶学性质.以黄胸鼠骨骼肌cDNA为模板,通过RT-PCR技术获得黄胸鼠Ldha基因编码序列,进行生物信息学分析后构建pET28α-Ldha重组表达质粒,导入大肠杆菌Escherichia coli BL21(DE3)中诱导表达,采用SDS-PAGE和Western Blot对表达蛋白进行鉴定,最后检测表达蛋白的酶学性质.结果显示,黄胸鼠Ldha基因编码区序列被成功克隆
The lockdown of large parts of Chinese economy beginning in late January 2020 lead to significant regional changes of aerosol loads,which suggests a reduction of backscatter and consequently a regional warming in the following months.Using local data and
饥饿胁迫对水生生物是一个十分普遍的现象,无论是环境变化或者是生殖洄游,诸多因素都会造成饥饿胁迫.为了探究饥饿胁迫对水生动物肝脏的影响,运用LC-MS代谢组学研究经过14 d饥饿胁迫后剑尾鱼Xiphopho-rus helleri肝脏内源性代谢物的变化,寻找差异代谢物以及相关的代谢通路.实验分为2组(对照组和饥饿组),每组24尾,对照组每日正常喂食,饥饿组禁食,共14 d.与对照组相比,饥饿组共筛选出8种具有显著性差异的代谢物:D-甘露糖、α-D-半乳糖、蔗糖、亚油酸、L-精氨酸、D-葡萄糖、牛磺酸和脱氧肌
In this study,influence of back-wall clearance,CWL(Critical Water Level)and air content in water on flow patterns in a pump intake has been investigated experimentally and theoretically for different cases.The statistical data show that CWL for a two-phas
High power electronics units generate high-density heat flux,which poses a significant threat to the reliability of these devices.The vapor chamber(VC)has a very high heat transfer rate and has a wide range of applications in the heat dissipation of elect
The through-flow analysis is an important part in the compressor design process.In this part,lots of empirical models are used to predict the compressor aerodynamic performances.These models are all based on the early experimental results of low-load and
In this paper,an ejector enhanced two-stage auto-cascade refrigeration cycle(EARC)using ternary mixture R600a/R32/R1150 is proposed for application of-80℃freezing.In EARC cycle,an ejector was employed to recover the expansion work in the throttling proces
集群行为与动物生存繁衍密切相关,对于动物保护研究具有重要意义.2014年10月—2015年10月,利用红外相机技术对贺兰山国家级自然保护区马鹿阿拉善亚种Cervus elaphus alashanicus的集群行为进行了为期1年的研究.结果发现,贺兰山马鹿阿拉善亚种平均集群数量为1.40只±1.04只,最大集群数量为11只,其中集群大小为1~2只的出现频次最高.通过对视频和图片处理,共识别出6种集群类型,其中单个雄性群和单个雌性群的出现频次占比最高.平均集群大小与季节、不同季节集群类型大小之间的差异均不显
Based on experimental data,numerical simulations by turbulent air flowing across staggered tube bundle composed of twisted elliptical tube(TET)with constant tube wall temperature are conducted in present study.Parametric study on the thermal-hydraulic cha