Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardiov

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:fang19902009
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Implantable cardioverter defibrillator (ICD) is the only effective therapy in patients with life threatening ventricular arrhythmias. Inappropriate detection and therapy by ICDs are the most common causes of side effects that affect the quality of life in ICD recipients. This study evaluated the incidence and causes of inappropriate detection and therapy by ICDs in patients in our hospital.Methods From January 2000 to December 2005, fifty patients who received ICD implantation for ventricular arrhythmias for prevention of sudden cardiac death were evaluated in this study. Each ICD was programmed using clinical arrhythmic and cardiac data of the patient before discharge. Patients were followed up by standard schedule after implantation and all data retrieved from each device were collected and saved for further analysis. Results No arrhythmic event was detected in 12/50 (24%) patients during the period of follow-up. Among the remaining patients, 11 (22%) experienced inappropriate detections and therapies during follow-up in this study. ICD detected 383 ventricular tachyarrhythmia (VT) and 108 ventricular fibrillation (VF) episodes and delivered 678 therapies. In VT group, ICD delivered 413 antitachycardiac pacings (ATPs) and 118 shocks, among which 78 ATPs and 9 shocks were initiated by 55/383 (14.3%) inappropriate detections. In VF group ICD delivered 147 shocks, among which 56 shocks were initiated by 28/108 (26.9%) inappropriate detections. Overall, more than 50% of these episodes were caused by atrial fibrillation (AF) with rapid ventricular response, followed by electromagnetic or myopotential interference. In addition, most inappropriate therapies occurred within one year after ICD implantation.Conclusions About one fifth of patients experienced ICD inappropriate detection and therapy after implantation. The main cause was AF with rapid ventricular response, followed by electromagnetic or myopotential interference.
其他文献
Background Early diagnosis and timely treatment are important for improving therapeutic efficiency of prostate cancer. DNA array is a new bio-technology for dis
Genetic epidemiology researches such as twin studies, family-clustering of hepatitis B virus (HBV) infection studies and ethnic difference studies have provided
AIM:To evaluate the protective effects of preconditioning by α-lipoic acid (LA) in patients undergoing hepatic resection under inflow occlusion of the liver.ME
The objective of this report is to give an overall view of the epidemiological, clinical, diagnostic and therapeutic features of Cytomegalovirus (CMV) infection
AIM:To detect distribution and relative frequency of endocrine cells in gastrointestinal tract of flower fish (Pseudophoxinus antalyae ).METHOIS:The intestinal
AIM:To assess the efficacy of different schedules of consensus interferon (CIFN) plus ribavirin in retreating chronic hepatitis C patients who relapsed after re
AIM: To study the loss of heterozygosity (LOH) on 12p12-13 in Chinese colon carcinoma patients.METHODS: DNA was extracted from 10 specimens of cancer tissue, 10
AIM: To evaluate magnetic resonance cholangiopancreatography (MRCP) findings in conjunction with magnetic resonance (MR) images in autoimmune pancreatitis (AIP)
AIM: To evaluate the effect of antisense vascular endothelial growth factor (VEGF) RNA (PCMV-FGEV)transfection on the profile of hepatocellular carcinoma (HCC)