美国ORE公司制造的超声波流量计,适用于管道和明渠。它利用超声波技术来测量多条相互平行声道上的平均流速,并计算过水流量。 当对流量计进行修理时,应根据状态灯的指示情况和显示的状态码数值,进行故障原因分析。1 状态灯 打开电源开关,检查位于声路连结器面板左侧的绿色电源指示灯。这些灯指示了系统各种电源的工作情况。正常情况下,3个灯都应亮。若3个灯都不亮,则检查是否有电。若有电,检查系统的保险丝,若保险丝是好的,就可能是系统电源坏了。
American ORE company made ultrasonic flowmeter, suitable for pipelines and open channels. It uses ultrasound technology to measure the average velocity of multiple parallel channels and calculate the amount of water flow. When repairing the flowmeter, the fault light should be analyzed according to the condition of the status light and the status code displayed. 1 Status light Turn the power switch on and check the green power light located on the left side of the sound path connector panel. These lights indicate the system a variety of power work. Under normal circumstances, all three lights should be on. If all three lights are off, check for power. If you have electricity, check the system fuse, if the fuse is good, it may be the system power is broken.