论文部分内容阅读
结合 3 0 95 TM多变量变送器配套阿纽巴流量传感器在某转油站天然气外输标准体积流量计量中的应用实例 ,通过天然气流量理论计算值、变送器流量计算测试值和变送器实际差压流量校验值三组流量数据的比较 ,提出了 3 0 95 TM 多变量变送器的软件安装、数据组态、量程范围设定和仪表校验等方法以及注意事项。
Combined with 3 0 95 TM multivariable transmitter supporting An Niuba flow sensor in a gas station natural gas standard volume flow measurement application example, through the theoretical calculation of natural gas flow, the transmitter flow calculation test value and transmission The actual differential pressure flow rate calibration value comparison of three sets of flow data, put forward the software installation, data configuration, range setting and instrument calibration method of 3 0 95 TM multivariate transmitter and precautions.