Feasibility of establishing cerebral ischemia models by using aerocyst-blocking bilateral ascending

来源 :中国神经再生研究(英文版) | 被引量 : 0次 | 上传用户:yzoryanzii
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
BACKGROUND: The cerebral ischemia and ischemia/reperfusion animal models are used to simulate the human cerebrovascular diseases is one of the popular topics of neurological science recently. To study the pathophysiology, pathogenesis, prophylaxis and treatment of ischemic cerebrovascular diseases and to establish the ideal animal model that is the most similar to the human cerebral ischemia, are the topics that the people generally cared about.OBJECTIVE: To evaluate the effects of aerocyst-blocking bilateral ascending pharyngeal artery on the establishment of cerebral ischemia models by using digital subtraction angiography (DSA), magnetic resonance diffusion-weighted imaging (DWI) and magnetic resonance perfusion-weighted imaging (PWI). DESIGN: Repetitive measure animal experiment.SETTING: Zhongshan Hospital Affiliated to Dalian University.MATERIALS: The experiment was carried out in the Animal Laboratory (Provincial Laboratory),Zhongshan Hospital of Dalian Univeristy from January to May 2006. A total of 14 domestic piglets, of 6 months old, weighing 12 - 15 kg, of either gender, were selected from Animal Experimental Center, Dalian University. Multistar T.O.P digital subtraction angiography machine was provided by Siemens Company,German.METHODS: Aerocyst-blocking bilateral ascending pharyngeal artery was used to establish cerebral ischemia models. And then, Multistar T.O.P. DSA was used for imaging of cerebral vessels before blocking, during blocking and at 0.5 and 2 hours after ischemia perfusion. GE Signa 1.5 T supraconduction magnetic resonance imaging was used for DWI examination; in addition, PWI was used based on focal sites and areas.Otherwise, magnetic resonance imaging (MRI) was used to detect signal changes of T1WI and T2WI in ischemic areas.MAIN OUTCOME MEASURES: Analytic results of DSA, DWI, PWI and MRI.RESULTS: All 14 experimental piglets were involved in the final analysis. ① DSA: The blood flow of bilateral ascending pharyngeal arteries and its branch were blocked at blocking phase, which restored 0.5 and 2 hours after reperfusion. ② DWI and PWI: There were no observable abnormalities in PWI and DWI at pre-blocking. Abnormal increased signals were found on both DWI and PWI at during and post-blocking. There were reduction in ADC and rCBF and delay in rTTP at all time points except pre-blocking. ③ MRI:There were no abnormal signals observable at any time of pre- and post-blocking in T1WI and T2WI.CONCLUSION: It is feasible to establish this kind of animal experimental models, and it can simulate the ischemic state; meanwhile, the existence and extent can be showed directly by DSA, DWI, and PWI.
其他文献
目的 比较格列吡嗪、二甲双胍、阿卡波糖二联用药治疗2型糖尿病的临床疗效.方法 随机抽取来我院就诊单纯用一种降糖药控制血糖不佳的患者60名,将其随机分为三组,疗程12周.定
在圆坯连铸中,结晶器电磁搅拌器( M-EMS)是常见的改善钢流内流场的手段.众所周知,液芯的流动对最终产品的质量有着重要影响,用M-EMS能优化凝固前沿的流速,进一步促进柱状晶向
本文以东阳市供电局配网自动化为例,介绍县级配网自动化的特点,总结建设过程中遇到的问冠,并提出相应对策。
我们都知道,人的眼睛存在视觉暂留现象,正因为眼睛的反应迟钝,才丰富了人的视觉感受。LED摇摇棒很好地利用了人眼的视觉暂留特性,是人感到了美的享受。下面是基于STC89C52单片机
用电与人们的生活息息相关,但是传统的电表的管理系统存在诸多的问题,拖欠电费的情况时有发生,手工抄表耗时耗力,对电力部门的管理工作的开展十分不利,而智能电表的运用在一定程度
缺相是三相异步电动机负载运行时常见的故障之一,因缺相运行而造成的电动机烧毁事故在生产中占很大比佣。本文针对传统的热继电器缺相保护存在反应慢、误动作或不能及时切断电
BACKGROUND: Pattern- visual evoked potential (PVEP) can reflect the functional status of retinal ganglial cells (RGC) and visual cortex, and is an objective exa
目的:观察化消合剂的安全性以及对放射性肝炎的预防作用.方法:随机分为两组,每组35例,放疗方法相同,中药化消合剂组(简称中药组)用化消合剂内服;单纯放疗组(简称单放组),仅单
通过对大庆油田化工集团某工程,冬季期间供热采暖系统已联运情况下对采暖管线进行管道连头作业,对该特殊情况下的带压开孔施工方案进行分析,总结对策及施工成功的经验,对运行
本文在综述临终关怀产生必然性的前提下,通过对临终关怀理念的阐述,旨在提出临终关怀的实施和护理人员死亡观之间的关系,并进一步述及护理人员的死亡观及影响因素,得出我国护