【摘 要】
:
In DC transmission systems, AC filters can effectively reduce the hazards of harmonics, and compensate the reactive power requirements of the converters, thus t
【机 构】
:
State Power Economic Research Institute
【基金项目】
:
Project supported by Science and Technology Project of SGCC;
论文部分内容阅读
In DC transmission systems, AC filters can effectively reduce the hazards of harmonics, and compensate the reactive power requirements of the converters, thus the type and parameter choice of the filters is important. Therefore, based on the system conditions of Jinping-Sunan ±800 kV UHV DC (ultra-high voltage direct current) transmission project and the main harmonics, three types of filters were designed. The parameters of filter components were determined according to the reactive power compensation. By calculating the filter performance and rating, the results show that the parallel tuning with greatly over-currents appears in the low vohage arm of BP11/13 filter. In order to avoid this kind of danger, a filter named BP1l/BP13 is designed. Studies show that this type of filter can fully meet the filter performance requirements and avoid the ovevcurrent. It is concluded that the filter BP11/BP13 can reduce the rating of the components and enhance the stability in the long-term operation.
其他文献
The Chinese coastal regions are the high risk areas of natural disasters for their lowland and weak and sensitive eco-evironment. The relative sea-level rising
广州市实现城市生态可持续发展总目标的任务和重点包括两方面:一方面系统而有重点地防范生态风险,缓冲和抗御自然灾害与极端气候等,解决制约广州城市发展的重点和潜在的战略
Artificial intelligence has been used to obtain background factors (basic environmental factors) from landslide specialists. A 3D visible evaluation map may be
Collecting waste water with a certain concentration of organic pollutants COD (chemical oxygen demand), static adsorption, static biodegradation and dynamic soi
Transient DC voltage measurement error has been observed several times ever since Xiangjiaba--Shanghai ±800 kV UHVDC project started its commercial operation.
超高压交流/特高压直流同塔多回输电线路下层500kV交流导线平行处的塔身宽度(简称塔宽)比单一500kV线路铁塔增大I倍以上,同时下层带电作业间隙还存在着上层±800kV直流线路产生的
The aggregation behavior of various acid extractants in the solvent extraction systems of metal ions is re-examined and explained according to knowledge obtaine
Both correlation analysis and case study indicate that Antarctic oscillation (AAO) is closely related with summer rainfall in eastern China. When AAO is stronge
为研究特高压(UHV)分裂导线宽频带的电晕电流特性,进而计算导线的电晕损失,设计研制了1套基于全球定位系统(GPS)同步时钟的宽频带电晕损失测量系统。该系统通过全球定位系统(GPS)同步
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥