目的分析手术室腔镜不同消毒灭菌方法的效果。方法选取医院手术室内的腔镜器械120件为研究对象,随机分为对照组和观察组,每组60件,对照组采用2%戊二醛浸泡,观察组采用等离子灭菌机,比较2种消毒灭菌方法的效果。结果观察组清洁率为96.67%,高于对照组的81.67%(P<0.01);观察组灭菌合格率为98.33%,高于对照组的86.67%(P<0.05)。结论等离子灭菌机相比于2%戊二醛浸泡对手术室内的腔镜进行消毒可以获得更好的消毒灭菌效果,有利于手术室内消毒灭菌工作的有效开展。
Objective To analyze the effect of different methods of disinfecting and sterilizing the laparoscope in the operating room. Methods One hundred and twenty endoscopic instruments in the hospital operation room were selected as study objects. They were randomly divided into control group and observation group, with 60 in each group. The control group was soaked with 2% glutaraldehyde. The observation group was treated with a plasma sterilizer. The effect of disinfection and sterilization methods. Results The cleanliness rate of the observation group was 96.67%, which was higher than that of the control group (81.67%) (P<0.01). The sterilization pass rate of the observation group was 98.33%, which was higher than that of the control group (86.67%) (P<0.05). Conclusion Compared with the 2% glutaraldehyde immersion, the plasma sterilizing machine can sterilize the laparoscope inside the operating room to obtain a better disinfection and sterilization effect, which is beneficial to the effective development of the sterilization and sterilization in the operating room.