论文部分内容阅读
Purpose: To measure episcleral venous pressure (EVP) in normal Chinese people.Methods: EVP was measured in 110 eyes of 74 subjects distributed in seven age groups from 10 to 80 years using episcleral venomanometer (EV-310). The differences in EVP values were analyzed with age and either eye.Results: EVP values of the 110 eyes appeared as normal distribution. The value x ± SD was (9. 11 ± 1.22) mmHg, and the 95% normal value range was 6. 73 mmHg~11.50mmHg. No statistically significant difference of EVP was found in the seven age groups.And there was no statistically significant difference of EVP between the right and left eyes.Conclusions: The value x ± SD of EVP in Chinese normal eyes is 9. 11 mmHg ± 1.22mmHg. The normal value of EVP does not vary with age and either eye.