相量测量单元(phasor measurement unit,PMU)的广泛应用,为实现智能电网的动态安全监控提供了数据基础,其动态行为是系统安全控制的关键。然而经分析,在系统动态情况下,一方面,传统的离散傅里叶变换(discrete Fouriertransform,DFT)算法会因频谱泄漏产生误差,引起振荡分析错误;另一方面,在广域测量系统(wide area measurement system,WAMS)中,子站PMU将相量上传主站时,有可能发生频率混叠,影响基于PMU的各种应用。数字滤波器的应用可以解决上述2个问题。首先阐述含有数字滤波器的PMU系统框架;其次分析动态下相量计算及相量上传中的问题,并论证数字滤波器解决上述问题的可行性,指出数字滤波器的必要性;然后揭示数字滤波器选取对不同应用的影响;最后给出仿真算例。
The wide application of phasor measurement unit (PMU) provides the data foundation for the dynamic safety monitoring of smart grid. Its dynamic behavior is the key of system security control. However, under the system dynamics, on the one hand, the traditional Discrete Fourier Transform (DFT) algorithm generates errors due to spectrum leakage and causes oscillation analysis errors; on the other hand, in the wide-area measurement system area measurement system (WAMS), when the substation PMU uploads the phasor to the master station, frequency aliasing may occur, affecting various applications based on the PMU. The application of digital filter can solve the above two problems. Firstly, the frame of PMU with digital filter is expounded; Secondly, the problems of dynamic phasor calculation and phasor upload are analyzed, and the feasibility of digital filter to solve the above problems is demonstrated, and the necessity of digital filter is pointed out. Then digital filter The influence of the device selection on different applications is given. Finally, a simulation example is given.