Comparison of the flaps made by femtosecond laser and automated keratomes for sub-bowman keratomileu

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:ZS54902
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Thin-flap laser in situ keratomileusis (LASIK) is the new trend of refractive error correction surgery,the formation of ceal flap is crucial for a success of LASIK surgery.This study aimed to assess and compare the variations of LASIK flap created by the IntraLase femtosecond laser,Moria One Use-Plus SBK and Moria M2 Single-Use 90 μm-head microkeratome using Anterior segment optical coherence tomography (Visante OCT).Methods One hundred and sixty-one eyes of 81 consecutive patients were enrolled in this prospective study and randomly divided into three groups depending on the flap creation method:flap creation with the the IntraLase femtosecond laser (IntraLase group,59 eyes),flap creation with the Moria One Use-Plus SBK (SBK group,44 eyes),and flap creation with the Moria M2 Single-Use 90 μm-head microkeratome (M2SU90 group,58 eyes).The nominal flap thickness was 110 μm for all patients and for the three devices.One month after surgery,Visante OCT was used to measure the flap thickness at 20 locations on each cea and the results were assessed for uniformity,regularity,and accuracy.Results At 1 month after surgery,the mean central flap thickness was (111±3) μm in the IntraLase group,(114±8) μm in the SBK group,and (118±13) μm in the M2SU90 group respectively.The flaps in the IntraLase group and the SBK group were more regular,showing an almost planar configuration,than the meniscus-shaped flaps in the M2SU90 group.The maximum deviation from the intended flap thickness (110 μm) was 6 μm in the IntraLase group,10 μm in the SBK group,and 20 μm in the M2SU90 group respectively.A difference greater than 20 μm was observed in 0.42% of measurements in the I ntraLase group; 2.95% of the measurements in the SBK group and 21.12% of measurements in the M2SU90 group.Conclusions The flaps created by the IntraLase femtosecond laser and Moria One Use-Plus SBK are more uniform;more regular,and more accurate than those created by the Moria M2 Single-Use 90 μm-head microkeratome.The first two methods can make precise flaps for Sub-Bowman Keratomileusis.
其他文献
介绍了我国汽车检测诊断设备的现状及对策,说明了汽车检测设备的发展趋势.
以4,6-二硝基苯并连三唑-1-氧化物(DNBTO)为原料,通过复分解、取代、硝化-水解反应设计并合成了未见文献报道的新化合物4,6-二硝基苯并连三唑-3-偕二硝甲基-1-氧化物(TNBTO);
就高速公路养护管理体制与分工提出了自己的观点:为适应公路发展和特性的需要,应该建立一支属于高速公路自己的专业化养护队伍;从责、权、利和高速公路营运管理的需要出发,各
目的探讨高血压病及高血压合并心律失常患者血清脂联素水平,及其与心脏重构的相关性。方法选取原发性高血压病患者71例,分为单纯高血压组(36例)及合并心律失常组(35例)。测定
伴随着城市建设的发展,建筑行业正处于快速发展阶段,在建筑的建造及使用过程中,消耗大量自然资源的同时,也给自然环境带来极大负担。因此,节能减排概念逐渐被社会各界积极倡
1“村村通自来水”工程意义重大,任务艰巨今年省人代会上,韩省长在政府工作报告中宣布:“启动村村通自来水工程,力争用三年左右的时间,让全省80%以上的村庄用上安全卫生的自