论文部分内容阅读
该仪器具有测量精度高,待测标本少,显示打印直观迅速等特点。由于结构较为复杂,数据的采集处理、工作顺序等均可由机内计算机完成。其自动化程度高,与计算机连接后可直接给出中文临床诊断疾病的参考报告。故障情况开机,温控系统开始工作,待温度正常(37°)C,后正确进行所需程序的输入(如参数、时间等量)。当仪器接到“2MODE”
The instrument has high measurement accuracy, less specimens to be tested, display and print quickly and intuitively. As the structure is more complex, data acquisition and processing, work order, etc. can be completed by the computer inside. Its high degree of automation, connected with a computer can be directly given Chinese clinical diagnosis of disease reference report. Fault conditions boot, temperature control system to work until the temperature is normal (37 °) C, after the correct procedures for the required input (such as parameters, such as the amount of time). When the instrument receives “2MODE”