Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiogra

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:nvhuang123
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concs are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA.Methods:Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE).Surgery was performed on all the patients.A five-point scale was used to assess image quality.The diagnostic accuracy ofDSCT angiography and TTE was compared with the surgical findings as the reference standard.A nonparametric Chi-square test was used for comparative analysis.P<0.05 was considered as a significant difference.The mean effective radiation dose (ED) was calculated.Results:Diagnostic DSCT images were obtained for all the patients.Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings.The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P>0.05),and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05),respectively.The mean score of image quality was 3.77 ± 0.83.The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv).Conclusions:In infants and children with IAA,prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.
其他文献
This paper presents the development of an urban river water quality model which considers the physical-biochemical processes within rivers and the incorporated
In this paper, with consideration of the nonlinear and non-stationary properties of the temperature time series, we employ the Hilbert-Huang Transform, based on
In this paper, a fluid structure interaction(FSI) model is used to study the internal flow field and the measurement performance of a multi-channel flow meter.
目的 比较喉罩-舒芬太尼联合丙泊酚与喉罩-氯胺酮联合丙泊酚静脉麻醉两种方法在体表整形手术中应用的优缺点.方法 40例择期行体表整形手术患者,随机分为喉罩-舒芬太尼联合丙
期刊
国内外对飞机地面载荷的研究主要是针对每个起落架的总载荷,鲜见对起落架各机轮载荷分配研究的文献,而工程上又迫切需要相关的针对飞机起落架机轮载荷分配的计算分析方法.在
The scalar transport phenomena in vertical two-dimensional flows are studied using the random walk method. The establi-shed Lagrangian model is first applied to
约束非线性优化问题,禁忌搜索算法和遗传算法次之,Hopfield神经网络算法效果最差,容易陷入局部最优解.