The Study of Dosimetric Characteristics for GMS BT-125-1 125I Radioactive Seed

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:yzoryanzii
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To investigate the dosimetric characteristics of GMS BT-125-1 I-125 radioactive seed,including dose rate constant,radial dose functions and anisotropy functions.Methods:Dosimetric parameters of GMS BT-125-1 I-125 seed including dose rate constant,radial dose functions and anisotropy functions were calculated using the Monte Carlo code of MCNP5.Monte Carlo calculations were also performed for the PharmaSeed BT-125-1 I-125 seed,PharmaSeed BT-125-2 I-125 seed and model 6711 I-125 seed.The dosimetric parameters of GMS BT-125-1 I-125 seed were compared with those of PharmaSeed BT-125-1 I-125 seed,PharmaSeed BT-125-2 I-125 seed and model 6711 I-125 seed.The measurements of dosimetric parameters were performed using thermoluminescent dosimeters(TLDs)for GMS BT-125-1 I-125 seed.The results were compared with those of Monte Carlo simulation.Results:The MCNP5 calculated dose rate constant of GMS BT-125-1 I-125 seed was 1.011.The experimental measured dose rate constant of GMS BT-125-1 I-125 seed was 0.967.For radial dose function,the difference between GMS BT-125-1 I-125 seed and PharmaSeed BT-125-2 I-125 seed were typically less than 2.0%with a maximum of 3.3%.The largest differences were 8.1%and 6.2%compared with PharmaSeed BT-125-1 and model 6711 I-125 seed,respectively.For anisotropy functions,the difference between GMS BT-125-1 I-125 seed and PharmaSeed BT-125-2 I-125 seed was typically <10%with a maximum of about 9.6%when,and 22.9%when.Compared with Monte Carlo simulation,the largest differences of radial dose functions and anisotropy functions were 14.5%and 29.1%,respectively.Conclusions:The measured dose rate constant,radial dose functions and anisotropy functions for GMS BT-125-1 I-125 seed showed good agreement with Monte Carlo calculated values except for the r=0.5 cm and.The dosimetric parameters of GMS BT-125-1 I-125 seed are similar to those of PharmaSeed BT-125-2 I-125 seed,PharmaSeed BT-125-1 I-125 seed and model 6711 I-125 seed.There are differences of dosimetric characteristics among different radioactive seeds mainly due to the different material and length of markers in the seed.
其他文献
会议
  Objective To study the intensity modulated rotary volume plan in the esophageal carcinoma radiotherapy.Methods Application of 0.6 cm3 finger ionization cham
会议
  Purpose:The most common type of cancer among women is breast cancer.Accurate assessment of skin dose in radiotherapy can provide useful information for clin
会议
  Purpose:To quantify the advantages in prescription dose escalation from helical tomotherapy(HT)compared to LINAC-based IMRT on nasopharynx cancer.Material a
会议
  Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic
会议
  Real-time monitoring of ablation effect,temperature distribution and ablated area in the tumor treatment is a core problem in microwave thermal ablation.Thr
会议
会议
  Purpose:To evaluate the impact of complexity indices on the plan quality and deliverability of the volumetric modulated arc therapy(VMAT),and to determine t
会议
  Objectives:Treatment of arterivernous malformation(AVM)of the brain is challenging due to the size and location of the nidus-proper and its proximity to the
会议
  INTRODUCTION The artifacts due to physiologic motion when using the Cartesian strategy of magnetic resonance imaging are well known [1] and many techniques
会议