按GB 7588—2003《电梯制造与安装安全规范》中9.3的规定:“钢丝绳曳引应满足以下3个条件:1)轿厢装载至125%8.2.1或8.2.2规定额定载荷的情况下应保持平层状态不打滑:2)必须保证在任何紧急制动的状态下,不管轿厢内是空载还是满载,其减速度的值不能超过缓冲器(包括减行程的缓冲器)作用时减速度的值;3)当对重压在缓冲器上而曳引机按电梯上行方向旋转时,应不可能提升空载轿厢。”为了满足上面的曳引条件,在设计曳引系数时应按GB 7588—2003《电梯制造与安装安全规范》中附录M的公式进行。即用于轿厢装载和紧急制动工况:T_1/T_2≤e~(fa)(1)
According to GB 7588-2003 “Elevator manufacturing and installation of safety norms” in the provisions of 9.3: “wire rope traction should meet the following three conditions: 1) car load to 125% 8.2.1 or 8.2.2 rated load conditions Should be kept flat under the condition of non-slippery: 2) It must be ensured that in any emergency braking condition, the value of deceleration shall not exceed the capacity of the bumper (including the stroke-reducing bumper), regardless of whether the car is empty or fully loaded When the weight is on the buffer and the hoisting machine rotates in the elevator up direction, it should be impossible to lift the hoisting car. ”In order to meet the above traction conditions, Coefficient should be GB 7588-2003 “elevator manufacturing and installation of safety norms” Appendix M formula. Ie for car loading and emergency braking conditions: T_1 / T_2≤e ~ (fa) (1)