论文部分内容阅读
摘要:在我国电力行业突飞猛进的发展下,国内电网基本实现了全面覆盖,10kV及以下配网电容的无功补偿在电网配置中有了较为广泛的应用,这在很大程度上减少了电能损耗问题,同时无功补偿也能够促进电力资源的合理利用,为我国可持续发展奠定基础。
关键词:10kV配网;无功补偿;节能
文章编号:1005-7277(2019)05-0084-03
Abstract:By leaps and bounds in the development of the electric power industry in our country, the domestic power grid basically achieved universal coverage, 10 kv and below distribution network reactive power compensation of capacitor in the power grid configuration have become more widely used, which largely reduces the power loss, reactive power compensation also can promote the rational use of power resources, lay a foundation for the sustainable development of our country.
Key words:10 kv distribution network; Reactive power compensation; Energy saving
随着社会经济的不断发展,人们对生活水平也提出了更为严格的要求,无论是社会发展,还是人们的生活都离不开电力能源,这在很大程度上加大了我国电能消耗。为了避免电力和能源的大量消耗,需要及时解决供电短缺问题,结合实际情况采取切实可行的措施。基于此,本文将针对10kV及以下配网电容无功补偿、及其节能进行分析,希望通过本文论述,能够为我国电力行业提供参考依据。
1 10kV及以下配网电容无功补偿的难点
1.1 限制条件多
针对10kV配电网的无功补偿来讲,需要综合考虑电压约束、基本功率平衡、以及各种客观条件的限制。以我国某地区为例,在对变电站位置进行选择时,虽然经过潮流计算优化,但由于该地区人口数量较多,无法实现假设线路,这样便会为无功补偿工作带来更大难度。除此之外,环境、能源、线损、以及线路容量等都会在一定程度上对10kV配网电容无功补偿造成影响。
1.2 短期内变化大
配电网与传输网相比,配电网直接向用户供电,配电网的负荷增长方式、运输速度、以及供电区域的具体分布,都会在短时间内产生较大的影响。因此,在10kV及以下配电网的无功补偿,需要对长期发展要求做出深入分析,其主要是为了确保配电网能够适应随时变化的环境,并结合实际情况对其进行调整。
2 10kV及以下配网电容无功补偿技术
工作人员要以实际情况为基础,建立科学合理的配电网补偿方案,以此来确保信息系统和运行维度满足实际要求,这样才能更加妥善的处理无功补偿问题。
2.1 全部变压器的380V侧低压补偿
具体来讲,最小负荷、一般负荷、以及最大负荷作为负荷运行的基本运行方式,相关技术人员正式开展相关工作中,需要结合不同负荷运行方式去集中确定,要确保补偿容量的并联操作,同时能够实现分组,合理利用并联电容器,加强提升补偿效果。除此之外,针对无功分组的运行补偿方式来讲,要求技术人员结合相关标准对其进行合理利用,以此来减少无功负荷在10kV线路中流通的实际运行长度和参数结构。如此一来,不仅能为电压升级提供保障,而且也能达到降低线损程度的目的。
2.2 100kVA以上变压器的380V侧低压补偿方式
由于我国部分农村电网的配电变压器普遍存在着分散问题,再加上整体运行结构过小的额定容量,因此相关人员在拟定补偿方案和计划时,需要站在经济性角度对其进行综合考虑。除此之外,在安装配电变压器低压侧过程中,需要对其进行独立安装,其主要是为了贯彻相关机制,达到并联电容器目的。在正式安装之前,还需要集中处理并联电容器的相关信息,为不同负荷运行方式确定的无功容量分组提供有效的保障。在对数据和参数进行分析和处理阶段,还需要以参数问题和运行层级结构为基础,确保其功能能够最大程度发挥出来,加强提升方案的规范性、有效性、及科学性。综上补偿方式,不仅能够更好的实现节约电能,提升供电企业经济效益,而且其经济性也较为突出。
2.3 10kV线路杆上无功补偿
这种补偿方式主要是在配电变压器高压侧节点和10kV线路加装由电容器组构成的线路补偿装置,在电杆上安装并联电容器组,从而实现双杆、单杆补偿。经实践表明,10kV线路杆上无功补偿存在着很多优点,比如:首先,能够实现提升配电网功率因数,减少无功电流,降低线路损耗,升高电压。其次,不會投入过多的成本。最后,作用于补偿线路上的无功功率,从而实现就地补偿,有效的降低了10kV线路能损问题。相对来说,10kV线路杆上无功补偿也存在着一定的缺点,首先,需要将其和其他补偿方式融合在一起。其次,环境等因素会对其造成一定的影响。最后,无法补偿变压器低压侧的无功。
3 10kV及以下无功补偿的节能
3.1 明确补偿容量
在设置无功补偿装置容量的过程中,需要结合实际情况,有效的降低线损。普遍来讲,无功补偿装置容量应为线路平均无功负荷的2/3。在对无功补偿装置进行安装之前,还需要相关人员对该线路的实际负荷情况进行全面了解,从而确定出最合理的无功补偿装置容量。
3.2 明确安装位置
在安装无功补偿装置过程中,要降低配网主线上的无功电流。无功补偿装置应装设在配网线路负荷的2/3处位置,并且每条配网线路仅安装一台无功补偿装置。如此一来,便能够对安装位置、及补偿容量做出有效的规划,同时也能够加强完善与优化电网运行阶段存在的线路损耗问题,提升电压质量,满足社会发展、及广大人民群众对电力的要求。
4 安装无功补偿装置的注意事项
4.1 采用单点补偿方式
针对农村地区来讲,在安装无功补偿装置之前,要结合实际情况,采用单点补偿方式并对其进行控制,值得注意的是,在正式补偿阶段应避免设置分组投切。
4.2 严格控制补偿容量
在对配网线路开展补偿作业时,需要相关人员严格对补偿容量做出控制,其主要原因是如果补偿容量过大,便会导致在用电低峰期,线路会出现过电压或者过补偿等问题,再加上电杆空间有限,如果在同一电杆上安装过多的电容器,会直接影响到电容器的散热,同时还会为电力系统的持续运行造成影响。针对10kV及以下的配电网来讲,可以利用150kvar及以下的电容器组。
总结
综上所述,无功补偿作为电力系统的重要组成部分,制定切实可行的配电网电容无功补偿方案,能够在很大程度上确保电力系统的安全可靠性,同时也能提升电力系统的经济效益。值得注意的是,不同的无功补偿方式也存在着不同的限制,因此还需要相关技术人员结合实际情况,科学合理的选择无功补偿方式。除此之外,我国配电网无功补偿方面仍然有很大的进步空间,还需要相关人员对其进一步研究,以此来更好的实现降耗节能。
参考文献
王涛.10kV及以下配网电容无功补偿及其节能[J].通讯世界,2016(01):146-147.
黄立.探究10kV及以下配网电容无功补偿与节能分析[J].科技与创新,2014(22):46+50.
刘凯.10kV及以下配网电容无功补偿及其节能[J].低碳世界,2017(20):82-83.
关键词:10kV配网;无功补偿;节能
文章编号:1005-7277(2019)05-0084-03
Abstract:By leaps and bounds in the development of the electric power industry in our country, the domestic power grid basically achieved universal coverage, 10 kv and below distribution network reactive power compensation of capacitor in the power grid configuration have become more widely used, which largely reduces the power loss, reactive power compensation also can promote the rational use of power resources, lay a foundation for the sustainable development of our country.
Key words:10 kv distribution network; Reactive power compensation; Energy saving
随着社会经济的不断发展,人们对生活水平也提出了更为严格的要求,无论是社会发展,还是人们的生活都离不开电力能源,这在很大程度上加大了我国电能消耗。为了避免电力和能源的大量消耗,需要及时解决供电短缺问题,结合实际情况采取切实可行的措施。基于此,本文将针对10kV及以下配网电容无功补偿、及其节能进行分析,希望通过本文论述,能够为我国电力行业提供参考依据。
1 10kV及以下配网电容无功补偿的难点
1.1 限制条件多
针对10kV配电网的无功补偿来讲,需要综合考虑电压约束、基本功率平衡、以及各种客观条件的限制。以我国某地区为例,在对变电站位置进行选择时,虽然经过潮流计算优化,但由于该地区人口数量较多,无法实现假设线路,这样便会为无功补偿工作带来更大难度。除此之外,环境、能源、线损、以及线路容量等都会在一定程度上对10kV配网电容无功补偿造成影响。
1.2 短期内变化大
配电网与传输网相比,配电网直接向用户供电,配电网的负荷增长方式、运输速度、以及供电区域的具体分布,都会在短时间内产生较大的影响。因此,在10kV及以下配电网的无功补偿,需要对长期发展要求做出深入分析,其主要是为了确保配电网能够适应随时变化的环境,并结合实际情况对其进行调整。
2 10kV及以下配网电容无功补偿技术
工作人员要以实际情况为基础,建立科学合理的配电网补偿方案,以此来确保信息系统和运行维度满足实际要求,这样才能更加妥善的处理无功补偿问题。
2.1 全部变压器的380V侧低压补偿
具体来讲,最小负荷、一般负荷、以及最大负荷作为负荷运行的基本运行方式,相关技术人员正式开展相关工作中,需要结合不同负荷运行方式去集中确定,要确保补偿容量的并联操作,同时能够实现分组,合理利用并联电容器,加强提升补偿效果。除此之外,针对无功分组的运行补偿方式来讲,要求技术人员结合相关标准对其进行合理利用,以此来减少无功负荷在10kV线路中流通的实际运行长度和参数结构。如此一来,不仅能为电压升级提供保障,而且也能达到降低线损程度的目的。
2.2 100kVA以上变压器的380V侧低压补偿方式
由于我国部分农村电网的配电变压器普遍存在着分散问题,再加上整体运行结构过小的额定容量,因此相关人员在拟定补偿方案和计划时,需要站在经济性角度对其进行综合考虑。除此之外,在安装配电变压器低压侧过程中,需要对其进行独立安装,其主要是为了贯彻相关机制,达到并联电容器目的。在正式安装之前,还需要集中处理并联电容器的相关信息,为不同负荷运行方式确定的无功容量分组提供有效的保障。在对数据和参数进行分析和处理阶段,还需要以参数问题和运行层级结构为基础,确保其功能能够最大程度发挥出来,加强提升方案的规范性、有效性、及科学性。综上补偿方式,不仅能够更好的实现节约电能,提升供电企业经济效益,而且其经济性也较为突出。
2.3 10kV线路杆上无功补偿
这种补偿方式主要是在配电变压器高压侧节点和10kV线路加装由电容器组构成的线路补偿装置,在电杆上安装并联电容器组,从而实现双杆、单杆补偿。经实践表明,10kV线路杆上无功补偿存在着很多优点,比如:首先,能够实现提升配电网功率因数,减少无功电流,降低线路损耗,升高电压。其次,不會投入过多的成本。最后,作用于补偿线路上的无功功率,从而实现就地补偿,有效的降低了10kV线路能损问题。相对来说,10kV线路杆上无功补偿也存在着一定的缺点,首先,需要将其和其他补偿方式融合在一起。其次,环境等因素会对其造成一定的影响。最后,无法补偿变压器低压侧的无功。
3 10kV及以下无功补偿的节能
3.1 明确补偿容量
在设置无功补偿装置容量的过程中,需要结合实际情况,有效的降低线损。普遍来讲,无功补偿装置容量应为线路平均无功负荷的2/3。在对无功补偿装置进行安装之前,还需要相关人员对该线路的实际负荷情况进行全面了解,从而确定出最合理的无功补偿装置容量。
3.2 明确安装位置
在安装无功补偿装置过程中,要降低配网主线上的无功电流。无功补偿装置应装设在配网线路负荷的2/3处位置,并且每条配网线路仅安装一台无功补偿装置。如此一来,便能够对安装位置、及补偿容量做出有效的规划,同时也能够加强完善与优化电网运行阶段存在的线路损耗问题,提升电压质量,满足社会发展、及广大人民群众对电力的要求。
4 安装无功补偿装置的注意事项
4.1 采用单点补偿方式
针对农村地区来讲,在安装无功补偿装置之前,要结合实际情况,采用单点补偿方式并对其进行控制,值得注意的是,在正式补偿阶段应避免设置分组投切。
4.2 严格控制补偿容量
在对配网线路开展补偿作业时,需要相关人员严格对补偿容量做出控制,其主要原因是如果补偿容量过大,便会导致在用电低峰期,线路会出现过电压或者过补偿等问题,再加上电杆空间有限,如果在同一电杆上安装过多的电容器,会直接影响到电容器的散热,同时还会为电力系统的持续运行造成影响。针对10kV及以下的配电网来讲,可以利用150kvar及以下的电容器组。
总结
综上所述,无功补偿作为电力系统的重要组成部分,制定切实可行的配电网电容无功补偿方案,能够在很大程度上确保电力系统的安全可靠性,同时也能提升电力系统的经济效益。值得注意的是,不同的无功补偿方式也存在着不同的限制,因此还需要相关技术人员结合实际情况,科学合理的选择无功补偿方式。除此之外,我国配电网无功补偿方面仍然有很大的进步空间,还需要相关人员对其进一步研究,以此来更好的实现降耗节能。
参考文献
王涛.10kV及以下配网电容无功补偿及其节能[J].通讯世界,2016(01):146-147.
黄立.探究10kV及以下配网电容无功补偿与节能分析[J].科技与创新,2014(22):46+50.
刘凯.10kV及以下配网电容无功补偿及其节能[J].低碳世界,2017(20):82-83.