铁路路基填料设计中,经常就地取材,在粉细砂为主的地区,常利用粉细砂作为填料,虽然粉细砂属于C组填料,但由于其粒径单一、级配不良,K30达不到规范标准,而且大型机械无法施工,需要对其进行改良。通过对粉细砂试验段掺入不同体积的A、B组(砾砂或碎石土)填料试验,结果表明K30值能得到不同程度的提高,达到设计要求,并有效解决施工困难的问题。
Of railway subgrade filler design, often drawn locally, in the fine sand-based areas, often use fine sand as filler, although the fine sand belongs to the C group packing, but because of its single particle size, poor grading, K30 up Not standard, and large machinery can not be constructed, need to be improved. The test results show that the K30 value can be improved to some extent by meeting the design requirements and effectively solving the problems of construction difficulties by incorporating different volume A, B groups (gravel or crushed stone) filler.