目的 分析影响双侧颈总动脉直径差的因素及其临床意义。材料与方法 46例患不同脑血管疾病的患者均行数字减影血管造影 ,同时行多普勒超声检查测量双侧颈总动脉 (commoncarotidartery ,CCA)直径。结果 脑血管造影正常组病人双侧CCA直径之差均小于 0 .7mm ,当双侧CCA直径之差大于 0 .7mm时 ,脑血管造影即可观察到不同的血管病变。结论 Willis环的变异和一些血管病变可影响双侧CCA的直径之差 ,当其值大于 0 .7mm时 ,应行进一步检查以期早期发现脑部血管病变。
Objective To analyze the factors influencing the diameter difference of bilateral common carotid artery and its clinical significance. MATERIALS AND METHODS 46 patients with different cerebrovascular diseases underwent digital subtraction angiography and the diameter of common carotid artery (CCA) was measured by Doppler echocardiography. Results The difference of bilateral CCA diameters between two groups was less than 0.7 mm in patients with normal cerebrovascular angiography. When the difference of bilateral CCA diameters was larger than 0.7 mm, different vascular lesions were observed with cerebral angiography. Conclusion Willis ring variation and some vascular lesions can affect the bilateral CCA diameter difference, when the value is greater than 0 .7mm, should be further examination to early detection of cerebral vascular lesions.