论文部分内容阅读
建设绿色节能变电站是我国电力行业的一项重要任务,其中确定变电站建筑的采暖空调需求是变电站节能的核心内容之一。为了确定变电站采暖空调负荷需求状况,以高海拔寒冷地区3个变电站典型建筑为分析对象,基于实地调研基础数据和DeST软件模拟方法,对3个变电站典型建筑冷热负荷的全年动态变化特征进行模拟分析,确定负荷指标并给出出现相互差异的原因。模拟分析得出的结果将为高海拔寒冷地区变电站建筑的节能设计提供一定的指导。
Building a green energy-saving substation is an important task for the power industry in our country. Among them, determining the demand for heating and air conditioning in substation construction is one of the core contents of substation energy conservation. In order to determine the substation heating and air conditioning load demand situation, taking the three typical substations in high altitude and cold area as the analysis object, based on the fieldwork basic data and DeST software simulation method, the annual dynamic load characteristics of the three buildings’ Simulation analysis, determine the load indicators and give the reasons for the emergence of mutual differences. The results of simulation analysis will provide some guidance for the energy-saving design of substation buildings in high altitude and cold area.