论文部分内容阅读
Research on a single cell Multi-gap Resistive Plate Chamber (MR PC)was carried out for the Time Of Flight detector (TOF) R and D of the STAR experi-ment. The property of the single chamber was tested with the test beam facility T10at CERN in Geneva. The MRPC was scanned with the test beam to get the efficiencyand time resolution at different position of the active area. The HV plateau was alsomeasured. The time resolution is 65 ps which satisfies the requirement of STAR. Theworking mechanism of the MRPC is also explained.