Abstract: Along with our country economy development, requirements of the residents housing level increasing, the comprehensive design direction in one of the many elements of residential design is also in the set of beautiful, practical and convenient, security and development. The electrical design is an important part in the design of Hyundai Residence, whether in the residential design process of electrical safety issues directly related to residential security. Based on the practical problems of existing in the design process, put forward some suggestions to strengthen the measures.
Key words: electrical design; target; lightning protection
中图分类号:TU2
前言:近年来随着我国的建筑规模迅速扩大,建筑能耗总量也在逐年上升。以上海市而言,建筑能耗已占到总能耗的25.4%,所以推行建筑节能势在必行、迫在眉睫。建筑电气能耗在建筑能耗中占有相当大的比例,因此建筑电气的节能设计就显得尤为重要。
一、建筑电气设计要达到的目标
1.住宅电气设计的设备选型应能满足居民在住宅居住期内(一般按30、50年考虑)用电的增长,以居民远期负荷发展为依据,以居民生活用电达到中等电气化水平为目标。
2.根据居民生活情况,使每户住宅的供电达到410kW的水平,并保证在住宅居住期内不再改造。
3.具有合格的电能质量,家用电器能正常工作。
4.为新建居民住宅电气设计提供参考,使电气安装一次达到要求,不搞重复建设。
二、现代建筑电气设计存在的问题分析
1、某些旧住宅在进行配电改造设计时,采用直敷布线,当导线垂直敷设时,未经任何保护就进入距地1.4m 的明装照明开关。不符合现行国家标准《低压配电设计规范》GB50054—95 的第 5.2.1 条第3 款“当导线垂直敷设至地面低于1.8m 时,应穿管保护”的规定。
2、忽视浴室的电气安全措施在浴室发生电击事故的危险机遇特别大,因为潮湿人体的接触电阻大都非常小,所以很小的接触电压也会发生严重的电击事故与死亡事故。由于这一缘故,浴室被称为电气安全的特殊场所,但我国却至今没有特殊场所的国家电气标准,仅在行业标准《民用建筑电气设计规范》(JGJ/T 16—92)(以下简称《民规》)有一些电气安全措施的规定。
3、由于住户搬进住宅后一般会装修,为避免浪费,只在灯位处布置灯座。我国正在大力推广实施绿色照明工程,对于家庭来说,紧凑型荧光灯是取代白炽灯的最好选择。但是由于种种原因,卡口灯座在更换光源时,稍不注意,就会电着人,加之紧凑型荧光灯的灯头是螺口,不能用卡口灯座,所以在住宅设计时应选用螺口灯座,以确保住户使用安全和方便住户更换光源。
4、暗敷线路按最近路线敷设时,由于住宅的面层比较薄,线路管线交叉不易处理;另外照明线路通常利用顶棚灯的接线盒进线分线,在住户铺设木地板时,往往将敷设在地坪内的管线打断,造成电气不安全和使用的不方便。暗敷线路沿板孔、墙缝垂直或平行于地面敷设,就可以避免上述问题的发生,因为管线交叉可以在墙缝中解决,而照明线路则在墙的拐弯处利用接线盒进行分线,而非顶棚灯的接线盒,这样住户也可根据《住宅使用说明书》中的配电平面图,了解进入灯具线路的具体方向和位置,从而避免在铺设木地板时将管线打断。
5、目前,住宅设计大量选用模数化配電箱,其中大部分型号是PZ30,但PZ30 是不应该在住宅中使用的。因为, PZ30 和PZ20 是同时开发的两个系列,分别按两种使用场合设计的, PZ20 按非熟练人员场合设计,主要用于家庭和类似场所; PZ30 则按熟练人员使用设计,主要用于工业场所。因此,只要电气间隙爬电距离足够,很多三相系统PZ20 能代替PZ30 系列。由此可见, PZ30 不应在住宅中使用。
三、针对现阶段我国住宅设计过程中电气安全问题的具体相关建议 1、电能表方面对于新住宅,优先采用长寿命、单相感应脉冲电能表 时于旧住宅,可以选用平均寿命不小于1O安培的感应电子型单相脉冲电能表。电能表规格的选择对于家庭用电容量较小的居民户,安装5(20)安培的电能表,保证在4kW以内可靠用电;用于用电容量在4kW、10kW内的居民户,安装10(40)安培的电能表。2、进户线问题表箱到各居民户门口接线盒的进户线采用截面积为lO平方毫米的铜芯绝缘线;对特殊用户特别配线。3相4线送进表箱内3相电力,出线按户数平均分配在2相负荷上,使3相负荷尽量保持平均;有特殊用电的用户可特殊对待。从表箱至每户接线盒的进户线,应根据现场实际情况,统一布局,安装要牢固、可靠,达到线进管、管进箱的要求。3、室内方面 室内布线应在基建施工时布置在墙内,配线不仅要使电能的输送可靠,而且要使线中布置合理、整齐、安装牢固,符合技术规范的要求,内线工程不能降低建筑物的强度、影响建筑物的美观,在施工前要考虑好线路与给排水管道、热力管道、风管道以及通讯线路布线等的位置关系。室内布线要根据线的绝缘皮的颜色分清火线、中性线和地线。选用的绝缘导线其额定电压应大于线路工程电压,导线的绝缘应符合线路的安装方式和敷设的环境条件,导线的截面应满足供电能力和供电质量的要求,还应满足防火的要求。配线时尽量避免导线有接头,因为由于工艺不良等原因,接头处往往电阻太大、发热量较大,引起事故,必须有接头时。可采用压接和焊接,务必使其接触良好,不松动,接头处不应受到机械力的作用,当导线穿过楼板时,应装设钢管或PVC管加以保护。当导线互相交叉时,为避免碰线,在每根导线上应套上塑料管或绝缘管,并需将套管固定。4、插座设置问题住宅内的插座应有足够的数量,以确保住户所有家用电器的需要而不再布线。厅、室的插座数量。客厅有4组1个单相3线和1个单相2线的组合插座,其他室内应在不同位置有2组。插座应有质量监督管理部门认定的防雷检测标志,壳体应使用阻燃的工程塑料,不能使用普通塑料和金属材料。插头、插座的定额电流应大于被控负荷电流,以免接入过大负载导致发热而烧坏或引起短路事故。电源引线与插头的连接人口处。应用压板压住导线,切忌直接连人插头内接线柱(螺丝)。插座宜固定安装,切忌吊挂使用 插座吊挂会使电线摆动,造成压导线的螺丝松动,并使插头与桶座接触不良。对于单相双线或3线的插座,接线时必须按照左中性线、右相(火)线上接地的方法进行,与所有家用电器的3线插头配合。电冰箱、洗衣机、电饭锅、饮水机等功率较大和需要接地的家用电器,应使用单独安装的专用插座,不能与其他电器共用一个多联插座。5、地线方面 为了使所有的用电装置都能够可靠接地,必须在楼层内安装独立的接地导线。每个楼层单元口和平房的每个表箱都应有可靠的接地,接地线引入每户居民住宅,在每户住宅中,形成单相3线制,接地线用不小于2.5平方毫米的铜芯绝缘线,并使每个配电板和每个3线插座都能可靠接地。
6、防雷装置安装的控制
对于大面积公共建筑这些属于二、三类的防雷建筑工程,综合分析该地区的气候状况,以一年为单位计算雷雨次数并预计建筑物念雷击次数,然后根据数据进行必要的防雷措施。只有采用科学有效地防雷措施才是建筑电力系统防雷工作的关键所在。因此在进行建筑物防雷设计时要严格按国内有关的电气设计规范对于一些民用建筑以及大型商业建筑的主要防雷措施进行细致分析以及对户外架空线路进行必要的防雷措施,并且建筑设计单位也要格外重视采取防雷改进措施的必要性,也只有建筑单位正确的实施了防雷技术,才能有效地确保防雷工作地可靠性。
结束语
随着经济水平的日趋发展,居民家用电器逐渐增多,住宅设计由原来纯照明向多功能的方向发展,电气线路、 配电设备也越来越复杂,但是建筑电气的设计问题涉及到安全的问题,所以要在设计过程中注意各方面的问题,以保证其质量。
作者简介:
姓名:赵巍巍 1977.12.7~,山东禹城人,2000年起在保定天威集团特变电气有限公司参加工作,主要从事变压器设计及技术支持。邮编 071056
关键词:电气设计;目标;防雷
Abstract: Along with our country economy development, requirements of the residents housing level increasing, the comprehensive design direction in one of the many elements of residential design is also in the set of beautiful, practical and convenient, security and development. The electrical design is an important part in the design of Hyundai Residence, whether in the residential design process of electrical safety issues directly related to residential security. Based on the practical problems of existing in the design process, put forward some suggestions to strengthen the measures.
Key words: electrical design; target; lightning protection
中图分类号:TU2
前言:近年来随着我国的建筑规模迅速扩大,建筑能耗总量也在逐年上升。以上海市而言,建筑能耗已占到总能耗的25.4%,所以推行建筑节能势在必行、迫在眉睫。建筑电气能耗在建筑能耗中占有相当大的比例,因此建筑电气的节能设计就显得尤为重要。
一、建筑电气设计要达到的目标
1.住宅电气设计的设备选型应能满足居民在住宅居住期内(一般按30、50年考虑)用电的增长,以居民远期负荷发展为依据,以居民生活用电达到中等电气化水平为目标。
2.根据居民生活情况,使每户住宅的供电达到410kW的水平,并保证在住宅居住期内不再改造。
3.具有合格的电能质量,家用电器能正常工作。
4.为新建居民住宅电气设计提供参考,使电气安装一次达到要求,不搞重复建设。
二、现代建筑电气设计存在的问题分析
1、某些旧住宅在进行配电改造设计时,采用直敷布线,当导线垂直敷设时,未经任何保护就进入距地1.4m 的明装照明开关。不符合现行国家标准《低压配电设计规范》GB50054—95 的第 5.2.1 条第3 款“当导线垂直敷设至地面低于1.8m 时,应穿管保护”的规定。
2、忽视浴室的电气安全措施在浴室发生电击事故的危险机遇特别大,因为潮湿人体的接触电阻大都非常小,所以很小的接触电压也会发生严重的电击事故与死亡事故。由于这一缘故,浴室被称为电气安全的特殊场所,但我国却至今没有特殊场所的国家电气标准,仅在行业标准《民用建筑电气设计规范》(JGJ/T 16—92)(以下简称《民规》)有一些电气安全措施的规定。
3、由于住户搬进住宅后一般会装修,为避免浪费,只在灯位处布置灯座。我国正在大力推广实施绿色照明工程,对于家庭来说,紧凑型荧光灯是取代白炽灯的最好选择。但是由于种种原因,卡口灯座在更换光源时,稍不注意,就会电着人,加之紧凑型荧光灯的灯头是螺口,不能用卡口灯座,所以在住宅设计时应选用螺口灯座,以确保住户使用安全和方便住户更换光源。
4、暗敷线路按最近路线敷设时,由于住宅的面层比较薄,线路管线交叉不易处理;另外照明线路通常利用顶棚灯的接线盒进线分线,在住户铺设木地板时,往往将敷设在地坪内的管线打断,造成电气不安全和使用的不方便。暗敷线路沿板孔、墙缝垂直或平行于地面敷设,就可以避免上述问题的发生,因为管线交叉可以在墙缝中解决,而照明线路则在墙的拐弯处利用接线盒进行分线,而非顶棚灯的接线盒,这样住户也可根据《住宅使用说明书》中的配电平面图,了解进入灯具线路的具体方向和位置,从而避免在铺设木地板时将管线打断。
5、目前,住宅设计大量选用模数化配電箱,其中大部分型号是PZ30,但PZ30 是不应该在住宅中使用的。因为, PZ30 和PZ20 是同时开发的两个系列,分别按两种使用场合设计的, PZ20 按非熟练人员场合设计,主要用于家庭和类似场所; PZ30 则按熟练人员使用设计,主要用于工业场所。因此,只要电气间隙爬电距离足够,很多三相系统PZ20 能代替PZ30 系列。由此可见, PZ30 不应在住宅中使用。
三、针对现阶段我国住宅设计过程中电气安全问题的具体相关建议 1、电能表方面对于新住宅,优先采用长寿命、单相感应脉冲电能表 时于旧住宅,可以选用平均寿命不小于1O安培的感应电子型单相脉冲电能表。电能表规格的选择对于家庭用电容量较小的居民户,安装5(20)安培的电能表,保证在4kW以内可靠用电;用于用电容量在4kW、10kW内的居民户,安装10(40)安培的电能表。2、进户线问题表箱到各居民户门口接线盒的进户线采用截面积为lO平方毫米的铜芯绝缘线;对特殊用户特别配线。3相4线送进表箱内3相电力,出线按户数平均分配在2相负荷上,使3相负荷尽量保持平均;有特殊用电的用户可特殊对待。从表箱至每户接线盒的进户线,应根据现场实际情况,统一布局,安装要牢固、可靠,达到线进管、管进箱的要求。3、室内方面 室内布线应在基建施工时布置在墙内,配线不仅要使电能的输送可靠,而且要使线中布置合理、整齐、安装牢固,符合技术规范的要求,内线工程不能降低建筑物的强度、影响建筑物的美观,在施工前要考虑好线路与给排水管道、热力管道、风管道以及通讯线路布线等的位置关系。室内布线要根据线的绝缘皮的颜色分清火线、中性线和地线。选用的绝缘导线其额定电压应大于线路工程电压,导线的绝缘应符合线路的安装方式和敷设的环境条件,导线的截面应满足供电能力和供电质量的要求,还应满足防火的要求。配线时尽量避免导线有接头,因为由于工艺不良等原因,接头处往往电阻太大、发热量较大,引起事故,必须有接头时。可采用压接和焊接,务必使其接触良好,不松动,接头处不应受到机械力的作用,当导线穿过楼板时,应装设钢管或PVC管加以保护。当导线互相交叉时,为避免碰线,在每根导线上应套上塑料管或绝缘管,并需将套管固定。4、插座设置问题住宅内的插座应有足够的数量,以确保住户所有家用电器的需要而不再布线。厅、室的插座数量。客厅有4组1个单相3线和1个单相2线的组合插座,其他室内应在不同位置有2组。插座应有质量监督管理部门认定的防雷检测标志,壳体应使用阻燃的工程塑料,不能使用普通塑料和金属材料。插头、插座的定额电流应大于被控负荷电流,以免接入过大负载导致发热而烧坏或引起短路事故。电源引线与插头的连接人口处。应用压板压住导线,切忌直接连人插头内接线柱(螺丝)。插座宜固定安装,切忌吊挂使用 插座吊挂会使电线摆动,造成压导线的螺丝松动,并使插头与桶座接触不良。对于单相双线或3线的插座,接线时必须按照左中性线、右相(火)线上接地的方法进行,与所有家用电器的3线插头配合。电冰箱、洗衣机、电饭锅、饮水机等功率较大和需要接地的家用电器,应使用单独安装的专用插座,不能与其他电器共用一个多联插座。5、地线方面 为了使所有的用电装置都能够可靠接地,必须在楼层内安装独立的接地导线。每个楼层单元口和平房的每个表箱都应有可靠的接地,接地线引入每户居民住宅,在每户住宅中,形成单相3线制,接地线用不小于2.5平方毫米的铜芯绝缘线,并使每个配电板和每个3线插座都能可靠接地。
6、防雷装置安装的控制
对于大面积公共建筑这些属于二、三类的防雷建筑工程,综合分析该地区的气候状况,以一年为单位计算雷雨次数并预计建筑物念雷击次数,然后根据数据进行必要的防雷措施。只有采用科学有效地防雷措施才是建筑电力系统防雷工作的关键所在。因此在进行建筑物防雷设计时要严格按国内有关的电气设计规范对于一些民用建筑以及大型商业建筑的主要防雷措施进行细致分析以及对户外架空线路进行必要的防雷措施,并且建筑设计单位也要格外重视采取防雷改进措施的必要性,也只有建筑单位正确的实施了防雷技术,才能有效地确保防雷工作地可靠性。
结束语
随着经济水平的日趋发展,居民家用电器逐渐增多,住宅设计由原来纯照明向多功能的方向发展,电气线路、 配电设备也越来越复杂,但是建筑电气的设计问题涉及到安全的问题,所以要在设计过程中注意各方面的问题,以保证其质量。
作者简介:
姓名:赵巍巍 1977.12.7~,山东禹城人,2000年起在保定天威集团特变电气有限公司参加工作,主要从事变压器设计及技术支持。邮编 071056