论文部分内容阅读
摘要:当前,建筑给排水与人们的生活息息相关,优质的安装施工质量和科学的管理是保障管网系统高效安全运行的必要条件,为了满足给排水工程施工技术要求,提高施工质量,需要施工人员不断学习,提高自身的技术素质,才能确保施工的安全、质量、稳定、灵活性,满足民用建筑给排水的发展需要。为此,本文针对高层建筑的给排水系统的多个方面进行了简要的探讨。
Abstract: at present, construction drainage with people's life, the high quality installation construction quality and scientific management is to ensure the safe operation of the pipeline network system high-efficient necessary conditions, in order to satisfy the water supply and drainage engineering construction technical requirements and improve the construction quality, need construction personnel keep learning and improve their technology quality, can guarantee the construction of safety, quality, stable, flexibility, meet the need of the civil building water supply. In this paper, the water supply and drainage system of the high-rise building many other aspects of was briefly discussed in this paper.
中圖分类号:TU97 文献标识码:A 文章编号:
1工程实例现以某商住楼给排水系统安装为例,该工程建筑面积52600m2,31层(地下室3层),rc框架结构,地下室为车库,1层~5层为商场,其中5层(夹层)作为管道转换层,6层~31层为住宅,该工程给排水系统安装特点为:管道类型多,安装操作技术难度大。现对该工程给排水系统的安装及施工技术作一些探讨。
1.1管道安装施工步骤熟悉图纸和有关技术资料→施工测量放线→沟槽开挖及管沟砌筑→配合土建预留孔洞及预埋铁件→管件加工制作→支架制作及安装→管道预制及组成→管道敷设安装→管道与设备连接→自控仪表及其管道安装→试压及清(吹)洗→防腐和保温→调试和试运转→竣工验收。
1.2给水设备的安装室内给水系统是由下列各部分组成:引入管、水表节点、供水设备(水泵)、水平主干管、立管、分支管及阀门器件。水泵房内的水泵、阀门等是用水枢纽,良好的安装质量,将能使工程的供水系统运作更可靠,人身及设备的安全使用寿命也更有保障,故对其安装提出如下要求:
1)设备安装前应对其有关资料和文件合格证进行核对检查。
2)设备不应有缺件、损坏和锈蚀,而转动部分应灵活无阻滞、卡住现象和异常声音。
3)对设备机组的安装是根据已经确定的水泵机组型号、机组的台数和机组的长度尺寸合理地规划其在水泵房中的安装位置和纵横排列形式。机组布置应使管线最短,弯头最少,管路便于连接和留有一定的走道和空间,以便于治理、操作和维修。
4)引入管与其他管道应保持一定的距离,如与室内污水排出管平行敷设,其外壁水平间距不小于1.0m,如与电缆平行敷设,其间距小于0.75m.
1.3给水管道的安装
1)管道安装之前需复测管道地沟,支架是否符合管道安装的标高、坡度和坡向。支架间距是否符合图纸和有关规范的要求。考虑到放空和管道运行的工艺需要。
2)法兰焊缝及其他连接件的设置应便于复检,并不得紧贴墙壁、楼板或管架。
3)管道安装施工过程中及完工后,应及时填写各种施工技术资料表格并经签证记录,埋地铺设的管道,应办理隐蔽工程验收,填写隐蔽工程记录并及时回填,这些施工技术资料均应整理存档。
4)穿过楼板、墙壁、基础、屋面的管道,均应加装套管进行保护,在套管内不得有管道接口。穿过屋面的管道应有防水层(或土建泛水)和防水帽,管道和套管之间的间隙宜用不燃材料填塞。
1.4排水管道的安装
1)排水塑料管必须按设计要求及位置装设伸缩节,如设计无要求时,伸缩节间距不得大于4m.
2)排水主干管及水平干管管道均应做通球试验,通球球径不小于排水管道管径的2/3,通球率必须达到100.
3)生活污水塑料管道的坡度必须符合设计或规范要求。
4)在立管上应每隔一层设置一个检查口,但在最低层和有卫生器具的最高层必须设置检查口,其中心高度距操作地面为1m,答应偏差±20mm,检查口的朝向应便于检修,在暗敷立管上的检查口应安装检查门。
5)排水通气管不得与风道或烟道连接,安装应符合规范。
1.5室内管道的布置该工程各种管道安装复杂,考虑管道的正确排列是管路安装中的一个重要环节,非凡是对于室内管道。由于管道设备多,使问题尤为突出,现将管道排列间距及避让的基本原则如下:气体管路排列在上,液体管路排列在下;热介质管路排列在上,冷介质管路排列在下;保温管路排列在上,不保温管路排列在下;金属管路排列在上,非金属管路排列在下。管线间距的确定。管线的间距以利于对管子、阀门及保温层进行安装和检修为原则。由于室内空间较小,其间距不宜过大,对于管子的外壁、法兰边缘及热绝缘层外壁等管路最突出部位距墙壁或柱边的净距不应小于100mm.对于并排管路上的并列阀门的手轮,其净距约100mm.管路相遇的避让原则:分支管路让主干管路;小口径管路让大口径管路;有压力管路让无压力管路;常温管路让高温或低温管路。
在首层室内地面回填及捣制混凝土前,应要求施工单位安装完成埋地的给排水管道,注意伸出地面管道的垂直度及对照图纸有无遗漏,安装位置是否符合现场要求。给水管必须做水压及通水试验,当符合要求时应及时给施工单位办理隐蔽工程验收手续,签发隐蔽验收记录。再要求施工单位将各预留管临时封堵好,配合土建堵孔洞和回填土。
要求所有埋地金属管,在安装前按设计要求做好防腐处理。敷设好的管道应及时进行灌水试验,注意观察管道水满后水位是否下降,检查管道各接口及管子本身有无渗漏。检查管道过墙壁和楼板处,是否按要求设置了金属或塑料套管(排水立管穿楼板处需设置钢套管),注意检查各预留孔洞和套管位置及大小是否符合图纸及现场要求,有无遗漏。安装在一般楼板处的套管,其顶部高出装饰地20mm即可,而安装在卫生间及厨房内的套管其顶部应高出装饰地面50mm,套管底部应与楼板底面平安装在墙壁内的套管,其两端应与饰面平。
1.6 主体装修施工阶段
主体装修施工阶段是给排水设置系统安装的阶段,管道经过建筑物的结构伸缩缝、抗震缝及沉降缝时要求设置补偿装置;安装U-PVC塑料排水立管时必须按设计、图纸要求的位置设置伸缩节,如无设计要求,伸缩节间距不得大于4m.在立管安装前,要求施工单位先打通该立管各楼层预留的孔洞,自上至下吊线,并弹出立管安装的垂直中心线,作为立管安装的基准线。立管安装后,均应检查其是否位于立管安装的垂直线上,在该立管垂直度及与墙之间的距离符合要求后,用管卡固定好。
及时将各层孔洞按施工规范及设计要求修补好。排水立管上应按规定设检查口,检查中心距地面一般为1100mm,并应高于该层卫生器具上边缘150mm;排水立管底部的弯管处需按要求设支墩。穿墙套管与管道之间缝隙宜用阻燃密实材料填实,且端面光滑。注意检查是否有管道的接口设置在套管内。
首层埋地管,地下室底板、电梯坑排水管,直接安装在楼板内的排水管,沉箱内排水管,吊顶内排水管,直接安装在墙体内的空调冷凝水管等排水管道在隐蔽前需做灌水试验,其灌水高度应不低于底层地面高度,满水15分后,再灌满延续5分,液面不下降为合格。当符合要求时及时给施工单位办理隐蔽工程验收手续排水立管及水平干管需做通球试验,通球直径不得小于排水管管径的2/3,通球率必须达到100%. .
2结语
当前,建筑给排水与人们的生活息息相关,优质的安装施工质量和科学的治理是保障管网系统高效安全运行的必要条件,而且也可以改进和弥补设计施工中的某些不足。为了满足给排水工程施工技术要求,提高施工质量,需要施工人员不断学习,提高自身的技术素质,才能确保施工的安全、质量、稳定、灵活性,满足民用建筑给排水的发展需要。只有这样,才能保证安装工程的质量,立足于建筑安装工程的基本建设
参考文献:
[1] 常智静,刘德庆.浅谈建筑给排水中应注意的问题[J]科技信息(科学教研).2009
[2] 杨天强.我国建筑给排水实用新技术[J]科技咨询导报.2010
Abstract: at present, construction drainage with people's life, the high quality installation construction quality and scientific management is to ensure the safe operation of the pipeline network system high-efficient necessary conditions, in order to satisfy the water supply and drainage engineering construction technical requirements and improve the construction quality, need construction personnel keep learning and improve their technology quality, can guarantee the construction of safety, quality, stable, flexibility, meet the need of the civil building water supply. In this paper, the water supply and drainage system of the high-rise building many other aspects of was briefly discussed in this paper.
中圖分类号:TU97 文献标识码:A 文章编号:
1工程实例现以某商住楼给排水系统安装为例,该工程建筑面积52600m2,31层(地下室3层),rc框架结构,地下室为车库,1层~5层为商场,其中5层(夹层)作为管道转换层,6层~31层为住宅,该工程给排水系统安装特点为:管道类型多,安装操作技术难度大。现对该工程给排水系统的安装及施工技术作一些探讨。
1.1管道安装施工步骤熟悉图纸和有关技术资料→施工测量放线→沟槽开挖及管沟砌筑→配合土建预留孔洞及预埋铁件→管件加工制作→支架制作及安装→管道预制及组成→管道敷设安装→管道与设备连接→自控仪表及其管道安装→试压及清(吹)洗→防腐和保温→调试和试运转→竣工验收。
1.2给水设备的安装室内给水系统是由下列各部分组成:引入管、水表节点、供水设备(水泵)、水平主干管、立管、分支管及阀门器件。水泵房内的水泵、阀门等是用水枢纽,良好的安装质量,将能使工程的供水系统运作更可靠,人身及设备的安全使用寿命也更有保障,故对其安装提出如下要求:
1)设备安装前应对其有关资料和文件合格证进行核对检查。
2)设备不应有缺件、损坏和锈蚀,而转动部分应灵活无阻滞、卡住现象和异常声音。
3)对设备机组的安装是根据已经确定的水泵机组型号、机组的台数和机组的长度尺寸合理地规划其在水泵房中的安装位置和纵横排列形式。机组布置应使管线最短,弯头最少,管路便于连接和留有一定的走道和空间,以便于治理、操作和维修。
4)引入管与其他管道应保持一定的距离,如与室内污水排出管平行敷设,其外壁水平间距不小于1.0m,如与电缆平行敷设,其间距小于0.75m.
1.3给水管道的安装
1)管道安装之前需复测管道地沟,支架是否符合管道安装的标高、坡度和坡向。支架间距是否符合图纸和有关规范的要求。考虑到放空和管道运行的工艺需要。
2)法兰焊缝及其他连接件的设置应便于复检,并不得紧贴墙壁、楼板或管架。
3)管道安装施工过程中及完工后,应及时填写各种施工技术资料表格并经签证记录,埋地铺设的管道,应办理隐蔽工程验收,填写隐蔽工程记录并及时回填,这些施工技术资料均应整理存档。
4)穿过楼板、墙壁、基础、屋面的管道,均应加装套管进行保护,在套管内不得有管道接口。穿过屋面的管道应有防水层(或土建泛水)和防水帽,管道和套管之间的间隙宜用不燃材料填塞。
1.4排水管道的安装
1)排水塑料管必须按设计要求及位置装设伸缩节,如设计无要求时,伸缩节间距不得大于4m.
2)排水主干管及水平干管管道均应做通球试验,通球球径不小于排水管道管径的2/3,通球率必须达到100.
3)生活污水塑料管道的坡度必须符合设计或规范要求。
4)在立管上应每隔一层设置一个检查口,但在最低层和有卫生器具的最高层必须设置检查口,其中心高度距操作地面为1m,答应偏差±20mm,检查口的朝向应便于检修,在暗敷立管上的检查口应安装检查门。
5)排水通气管不得与风道或烟道连接,安装应符合规范。
1.5室内管道的布置该工程各种管道安装复杂,考虑管道的正确排列是管路安装中的一个重要环节,非凡是对于室内管道。由于管道设备多,使问题尤为突出,现将管道排列间距及避让的基本原则如下:气体管路排列在上,液体管路排列在下;热介质管路排列在上,冷介质管路排列在下;保温管路排列在上,不保温管路排列在下;金属管路排列在上,非金属管路排列在下。管线间距的确定。管线的间距以利于对管子、阀门及保温层进行安装和检修为原则。由于室内空间较小,其间距不宜过大,对于管子的外壁、法兰边缘及热绝缘层外壁等管路最突出部位距墙壁或柱边的净距不应小于100mm.对于并排管路上的并列阀门的手轮,其净距约100mm.管路相遇的避让原则:分支管路让主干管路;小口径管路让大口径管路;有压力管路让无压力管路;常温管路让高温或低温管路。
在首层室内地面回填及捣制混凝土前,应要求施工单位安装完成埋地的给排水管道,注意伸出地面管道的垂直度及对照图纸有无遗漏,安装位置是否符合现场要求。给水管必须做水压及通水试验,当符合要求时应及时给施工单位办理隐蔽工程验收手续,签发隐蔽验收记录。再要求施工单位将各预留管临时封堵好,配合土建堵孔洞和回填土。
要求所有埋地金属管,在安装前按设计要求做好防腐处理。敷设好的管道应及时进行灌水试验,注意观察管道水满后水位是否下降,检查管道各接口及管子本身有无渗漏。检查管道过墙壁和楼板处,是否按要求设置了金属或塑料套管(排水立管穿楼板处需设置钢套管),注意检查各预留孔洞和套管位置及大小是否符合图纸及现场要求,有无遗漏。安装在一般楼板处的套管,其顶部高出装饰地20mm即可,而安装在卫生间及厨房内的套管其顶部应高出装饰地面50mm,套管底部应与楼板底面平安装在墙壁内的套管,其两端应与饰面平。
1.6 主体装修施工阶段
主体装修施工阶段是给排水设置系统安装的阶段,管道经过建筑物的结构伸缩缝、抗震缝及沉降缝时要求设置补偿装置;安装U-PVC塑料排水立管时必须按设计、图纸要求的位置设置伸缩节,如无设计要求,伸缩节间距不得大于4m.在立管安装前,要求施工单位先打通该立管各楼层预留的孔洞,自上至下吊线,并弹出立管安装的垂直中心线,作为立管安装的基准线。立管安装后,均应检查其是否位于立管安装的垂直线上,在该立管垂直度及与墙之间的距离符合要求后,用管卡固定好。
及时将各层孔洞按施工规范及设计要求修补好。排水立管上应按规定设检查口,检查中心距地面一般为1100mm,并应高于该层卫生器具上边缘150mm;排水立管底部的弯管处需按要求设支墩。穿墙套管与管道之间缝隙宜用阻燃密实材料填实,且端面光滑。注意检查是否有管道的接口设置在套管内。
首层埋地管,地下室底板、电梯坑排水管,直接安装在楼板内的排水管,沉箱内排水管,吊顶内排水管,直接安装在墙体内的空调冷凝水管等排水管道在隐蔽前需做灌水试验,其灌水高度应不低于底层地面高度,满水15分后,再灌满延续5分,液面不下降为合格。当符合要求时及时给施工单位办理隐蔽工程验收手续排水立管及水平干管需做通球试验,通球直径不得小于排水管管径的2/3,通球率必须达到100%. .
2结语
当前,建筑给排水与人们的生活息息相关,优质的安装施工质量和科学的治理是保障管网系统高效安全运行的必要条件,而且也可以改进和弥补设计施工中的某些不足。为了满足给排水工程施工技术要求,提高施工质量,需要施工人员不断学习,提高自身的技术素质,才能确保施工的安全、质量、稳定、灵活性,满足民用建筑给排水的发展需要。只有这样,才能保证安装工程的质量,立足于建筑安装工程的基本建设
参考文献:
[1] 常智静,刘德庆.浅谈建筑给排水中应注意的问题[J]科技信息(科学教研).2009
[2] 杨天强.我国建筑给排水实用新技术[J]科技咨询导报.2010