论文部分内容阅读
贵刊1997年第6期刊登的“差压标尺计量单位改制对流量测量准确度的影响及处理”(以下简称《处理》)一文很有讨论的必要。1.《处理》文中提出的处理方法,从道理上讲是正确的,但在实际工作中是不能那样做也没必要那样做。实际做法是以换算差压信号来处理的。以该文所举实例
Your publication No. 6, 1997 published “differential pressure scale unit of measurement system flow measurement accuracy and impact of treatment” (hereinafter referred to as “treatment”) is a very necessary discussion. 1. The treatment proposed in the article “Handling” is rightly justified, but it can not be done in actual work nor is it necessary. The actual method is to convert the differential pressure signal to deal with. Take the example cited in this article