目的了解一种复方含氯消毒剂的杀菌效果与腐蚀性,进行悬液定量杀菌试验与金属腐蚀试验。方法用卫生部卫生与法规监督司的消毒技术规范进行检验。结果以含有效氯2000mg/L溶液作用45min或1500mg/L溶液作用60min,对枯草杆菌黑色变种芽胞的杀灭率均为100%;以含有效氯300mg/L溶液15min或200mg/L溶液作用20min,对悬液中金黄色葡萄球菌杀灭率均为100%;以含有效氯300mg/L溶液15min或100mg/L溶液作用20min,对悬液中大肠杆菌杀灭率均为100%。结论将该消毒剂于54℃放置14d,有效氯含量下降率为7.3%;该剂为杀菌效果、稳定性较好的消毒剂。
Objective To understand the bactericidal effect and corrosiveness of a compound chlorine-containing disinfectant, to conduct quantitative suspension test and metal corrosion test. The method was tested with the disinfection technical specifications of the Department of Health and Regulation Supervision of the Ministry of Health. Results The killing rate of Bacillus subtilis black mutant spores was 100% with the effect of containing 2000mg / L of effective chlorine for 45min or 1500mg / L for 60min, and the killing rate of Bacillus subtilis black mutant spores was 100% for 15min or 200mg / L containing effective chlorine. , And the killing rate of Staphylococcus aureus in the suspension was 100%. The killing rate of Escherichia coli in the suspension was 100% with 15min or 100mg / L solution containing effective chlorine 300mg / L and 20min respectively. Conclusion The disinfectant was placed at 54 ℃ for 14 days and its effective chlorine content decreased by 7.3%. The agent was a disinfectant with good bactericidal effect and stability.