【摘 要】
:
Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues. If applied in cooperation with clinical methods it provides optimization
【机 构】
:
PhysicsDepartment–PolytechnicInstituteofPortoSchoolofEngineeringRuaDr.AntonioBernardinodeAlmeida,431
【出 处】
:
JournalofInnovativeOpticalHealthSciences
论文部分内容阅读
Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues. If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures. This technique turns biological tissues more transparent through two main mechanisms — tissue dehydration and refractive index (RI) matching between tissue components. Such matching is obtained by partial replacement of interstitial water by a biocompatible agent that presents higher RI and it can be completely reversible by natural rehydration in vivo or by assisted rehydration in ex vivo tissues. Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary. Using a simple method, based on collimated transmittance and thickness measurements made from muscle samples under treatment, we have estimated the diffusion properties of glucose, ethylene glycol (EG) and water that were used to perform such characterization and discrimination. Comparing these properties with data from literature that characterize their diffusion in water we have observed that muscle cell membrane permeability limits agent and water diffusion in the muscle. The same experimental data has allowed to calculate the optical clearing (OC) efficiency and make an interpretation of the internal changes that occurred in muscle during the treatments. The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a considerable improvement of optical tomographic techniques with better contrast and in-depth imaging.
其他文献
We propose a linear mapping relationship between the polarization of the fundamental mode and the cylindrical vector (CV) modes on the first-order Poincaré sphere (FOPS) in fiber. The new method is based on the four-dimensional complex Jones matrices in t
基于串联(concat)操作的特征融合方法仅仅融合了相邻尺度的特征,并没有充分利用来自其他尺度的输出特征。并且,串联操作只是在通道维度上将不同尺度的特征连接,不能反映不同通道间特征的相关性和重要性。针对这些问题,提出了一种基于注意力机制的特征融合算法。该算法利用注意力机制来融合不同尺度的特征,通过对每个通道的特征进行权重分配来学习不同通道间特征的相关性。将基于注意力机制的特征融合算法与YOLO V
本文在确定颜色模糊性的基础上,用模糊算子的方法分析了用通俗语言描述的颜色标志,提出了一种颜色标志的定量方法。
In the quantum key distribution system, quantum channel is always affected by spontaneous Raman scattering noise when it transmits with classical channels that act as synchronization and data channels on a shared fiber. To study the effect of the noise ex
针对目前隧道内的漏缆卡具检测数据量大,人工检测效率低的问题,本文提出了一种基于改进SSD(Single Shot MultiBox Detector)算法的隧道漏缆卡具检测方法。该方法使用不同尺度的特征图检测卡具目标,并在网络宽度和网络深度上对SSD的网络结构加以改进。其主要通过结合Inception结构增加网路宽度;采用残差结构在提高网络深度的同时优化网络深度结构;使用深度可分离卷积和1x1卷积
研究了基于线结构光光条信度评价的相机曝光时间优化方法,将信度评价结果作为曝光时间优化的参考指标。结合光条切面服从高斯分布的特点,对已有光条信度评价模型进行改进,构建高斯信度评价模型;利用亚像素光条中心提取方法对不同曝光时间下采集到的光条图像进行光心提取,提取结果经高斯信度评价模型评价得到评价信度值C和灰度值R;分析曝光时间t对评价结果的影响机理,构建t-C、t-R变化模型,并通过分析变化模型得到了
Full-field x ray nano-imaging (FXNI) is one of the most powerful tools for in-situ, non-destructive observation of the inner structure of samples at the nanoscale. Owing to the high flux density of the third-generation synchrotron radiation facility, grea
本文是一篇教学论文, 旨在通过对具体实例中不同物理过程的分析来定性解释光导拓宽固体材料折射率引导光纤光谱、多孔光纤光谱、光子带隙光纤光谱和纳米线光谱的原理。
The propagation of a filamentary laser beam at an air-glass surface is studied by setting the incident angle satisfying the total reflection condition. The images of the trajectory of the filamentary laser beam inside the sample and the output far-field s