论文部分内容阅读
最近,我们对长春气象仪器厂提供的10支国产湿敏电容传感器和一支从芬兰进口的同类传感器进行了不同温度条件的静态测试。测试所用标准设备为分流法湿度发生装置。测试温度分别为20℃、-10℃和一30℃。每种温度条件都分升湿和降湿行程进行了三个循环测试,每个行程取7个测试点
Recently, we conducted a static test at different temperature conditions on 10 homemade humidity-sensitive capacitance sensors supplied by Changchun Meteorological Instrument Factory and one similar sensor imported from Finland. The standard equipment used for the test was a shunt method of humidity generation. The test temperatures were 20 ° C, -10 ° C and 30 ° C respectively. Each temperature conditions are sub-ashing and dehumidifying the trip three cycles of testing, each trip to take seven test points