论文部分内容阅读
AIM: The purpose of this study was to compare the diagnostic accuracy of biphasic multi-detector row helical computed tomography (MDCT), digital subtraction angiography (DSA) and Lipiodol computed tomography (CT) in detection of hypervascular hepatocellular carcinoma (HCC). METHODS: Twenty-eight patients with nodular HCC underwent biphasic MDCT examination: hepatic arterial phase (HAP) 25 s and portal venous phase (PVP) 70 s after injection of the contrast medium (1.5 ml/kg). They also underwent hepatic angiography and intra-arterial infusion of iodized oil. Lipiodol CT was performed 3-4 wk after infusion. MDCT images were compared with DSA and Lipiodol CT images for detection of hepatic nodules. RESULTS: The three imaging techniques had the same sensitivity in detecting nodules >20 mm in diameter. There was no significant difference in the sensitivity among HAP-MDCT, Lipiodol CT and DSA for nodules of 10-20 mm in diameter. For the nodules <10 mm in diameter, HAP-MDCT identified 47, Lipiodol CT detected 27 (x2 =11.3, P= 0.005 <0.01, HAP-MDCT vs Lipiodol CT) and DSA detected 16 (X2=9.09, P= 0.005<0.01 vs Lipiodol CT and x2=29.03, P=0.005<0.01 vs HAP-MDCT). However, six nodules<10 mm in diameter were detected only by Lipiodol CT. CONCLUSION: MDCT and Lipiodol CT are two complementary modalities. At present, MDCT does not obviate the need for DSA and subsequent Lipiodol CT as a preoperative examination for HCC.
AIM: The purpose of this study was to compare the diagnostic accuracy of biphasic multi-detector row helical computed tomography (MDCT), digital subtraction angiography (DSA) and Lipiodol computed tomography (CT) in detection of hypervascular hepatocellular carcinoma (HCC). METHODS : Twenty-eight patients with nodular HCC underwent biphasic MDCT examination: hepatic arterial phase (HAP) 25 s and portal venous phase (PVP) 70 s after injection of the contrast medium (1.5 ml / kg). They also underwent hepatic angiography and intra-arterial -arterial infusion of iodized oil. Lipiodol CT was performed 3-4 wk after infusion. MDCT images were compared with DSA and Lipiodol CT images for detection of hepatic nodules. RESULTS: The three imaging techniques had the same sensitivity in detecting nodules> 20 mm There was no significant difference in the sensitivity among HAP-MDCT, Lipiodol CT and DSA for nodules of 10-20 mm in diameter. For the nodules <10 mm in diameter, HAP-MDCT identified 47, Li Piodol CT detected 27 (x2 = 11.3, P = 0.005 <0.01, HAP-MDCT vs. Lipiodol CT) and DSA detected 16 (X2 = 9.09, P = 0.005 <0.01 vs. Lipiodol CT and x2 = 29.03, P = 0.005 < HAP-MDCT). However, six nodules <10 mm in diameter were detected only by Lipiodol CT. CONCLUSION: MDCT and Lipiodol CT are two complementary modalities. At present, MDCT does not obviate the need for DSA and subsequent Lipiodol CT as a preoperative examination for HCC