论文部分内容阅读
The effect of pH value on the CaM(Calmodulin) self assembled membrane Au electrode was studied by CV method, where the redox couple of Fe(CN) 3- 6/Fe(CN) 4- 6 was employed as a probe. The results indicated the formation of the self assembled monolayer of CaM that the structure of this membrane is different in various acid/base environment, and the stronger the base, the denser the membrane. The work is meaningful to detect CaM by using electrochemical method.
The effect of pH value on the CaM (Calmodulin) self assembled membrane Au electrode was studied by CV method, where the redox couple of Fe (CN) 3- 6 / Fe (CN) 4- 6 was employed as a probe. indicated the formation of the self assembled monolayer of CaM that the structure of this membrane is different in various acid / base environment, and the stronger the base, the denser the membrane. The work is meaningful to detect CaM by using electrochemical method.