论文部分内容阅读
文章介绍了VVER机组核电站一回路除碱系统的结构和性能特点,并详细阐述了总碱金属较高时阳床KBB10AT001和混床KBE50AT001的控制方式,并对除碱工况下的工艺调整方式进行了量化,优化了整个燃料循环周期内的工艺控制方式,保证了一回路总碱金属处于最佳状态。
This paper introduces the structure and performance characteristics of the first-out-of-base system of VVER unit nuclear power plant, and elaborates the control methods of positive bed KBB10AT001 and mixed bed KBE50AT001 when the total alkali metal is higher, and adjusts the process adjustment mode To quantify and optimize the process control throughout the fuel cycle cycle, to ensure that a total alkali metal circuit is in the best condition.