淄博—潍坊天然气管道在投运阴极保护系统前,在对其管道的保护电位和自然电位测试时,发现该段管线的个别地段保护电位明显偏低,管道电位低于正常状态的平均值-1.1V至-1.2之间。针对此现象,对其现场考证并做了分析,原因是由于缠绕镁带的主管被淹没在水里,形成了牺牲阳极,导致管道电位偏低。通过对套管穿越处进行风干及封堵处理,电位测试回复正常。
Before the ZP-Weifang Natural Gas Pipeline put into operation the cathodic protection system, when testing the protective potential and natural potential of its pipeline, it was found that the protection potentials of individual sections of this section of pipelines were obviously lower and the pipeline potential was lower than the average value of normal state -1.1 V to -1.2. In response to this phenomenon, the field of research and analysis of the reason for the analysis is due to the supervisor of wound magnesium band was submerged in water, forming a sacrificial anode, leading to the pipeline potential is low. Through the casing through the place for air-drying and sealing treatment, the potential test returned to normal.