Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy.The thermal performance was affected by many different design parameters,such as configuration type and borehole size of geothermal heat exchanger.These eventually determined the operation and cost efficiency of the geothermal heat exchanger system.The main purpose of this work was to assess the thermal performance of geothermal heat exchanger with variation of borehole sizes and numbers of U-tubes inside a borehole.For this,a thermal response test rig was established with line-source theory.The thermal response test was performed with in-line variable input heat source.Effective thermal conductivity and thermal resistance were obtained from the measured data.From the measurement,the effective thermal conductivity is found to have similar values for twopair type(4 U-tubes)and three-pair type(6 U-tubes)borehole heat exchanger systems indicating similar heat transfer ability.Meanwhile,the thermal resistance shows lower value for the three-pair type compared to the two-pair type.Measured data based resistance have lower value compared to computed result from design programs.Overall comparison finds better thermal performance for the three-pair type,however,fluctuating temperature variation indicates complex flow behavior inside the borehole and requires further study on flow characteristics.
Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configuration type and borehole size of geothermal heat exchanger. The ultimately determined the operation and cost efficiency of the geothermal heat exchanger system. The main purpose of this work was to assess the thermal performance of geothermal heat exchanger with variation of borehole sizes and numbers of U-tubes inside a borehole. For this, a thermal response test rig was established with line- source theory. The thermal response test was performed with in-line variable input heat source. Effective thermal conductivity and thermal resistance were obtained from the measured data. From the measurement, the effective thermal conductivity is found to have similar values for twopair type (4 U-tubes) and three-pair type (6 U-tubes) borehole heat exchanger systems are similar heat transfer the thermal resistance shows lower value for the three-pair type compared to the two-pair type. Measured data based resistance has lower value compared to computed result from design programs. pair type, however, fluctuating temperature variation indicates complex flow behavior inside the borehole and requires further study on flow characteristics.