论文部分内容阅读
【摘 要】镁电解车间在使用过程中不可避免的会遭到腐蚀。本文结合黑龙江海绵钛镁电解车间的工程,首先介绍了镁电解车间的基本组成,并分析了一般情况下镁电解车间产生腐蚀的主要原因,主要有:车间的湿热特征、腐蚀性气体的产生等。最后结合建筑工程设计详细的阐述了镁电解车间楼地面防腐蚀构造的基本做法。
【关键词】镁电解车间;楼地面;防腐构造
Floor Anti-corrosion Structure of Magnesium Electrolysis Plant for Heilongjiang Titanium Sponge
Gao Yan1,Ai Chun-Zhi1,Shen li-Yuan2
(1.Shenyang Aluminium &Magnesium Engineering & Research Institute Shenyang Liaoning 110001;
2.Liaoning province building design institute for research four design Shenyang Liaoning 110001)
【Abstract】Magnesium electrolysis plant is able to be corrosive inevitably in production process. Combining with the project of magnesium electrolysis plant for Heilongjiang titanium sponge in this paper, the basic composition of magnesium electrolysis plant is introduced firstly, and the prime reason of producing corrosive for magnesium electrolysis plant is analyzed in general condition, for example, moist heat character of plant, producing corrosive gas etc. Finally, basic method of floor anti-corrosion structure for magnesium electrolysis plant is represented detailedly combining with building project design.
【Key words】Magnesium electrolysis plant;Floor;Anti-corrosion structure
1. 工程概况
黑龙江海绵钛为中外合资项目,选址位于黑龙江省佳木斯市,一期工程生产15 kt/a海绵钛。二期建设规模海绵钛的生产能力为15 kt/a,最终形成30 kt/a海绵钛的生产能力,并建设钛锭和钛板坯10 kt/a的生产能力。
2. 镁电解车间组成
镁电解车间包括:电解车间及袋滤器室、精炼及熔剂制备、氯压机室、净气室、整流所。电解槽纵向配置在厂房靠窗户的两边,操作面在厂房中间。为便于通风换气屋顶设有天窗,两边设有自然通风道。采用二层标高为5.250m操作面,直流电母线、尾气烟道、氯气导管等配置在地面上,厂房跨度30m,天车轨顶标高为13.850m。
3. 镁电解车间腐蚀产生的原因
镁电解车间厂房具有湿热特征,在生产过程中会产生侵蚀性气体如Cl2 (氯气)和HCl(氯化氢)和潮湿的导电的氯气灰尘,在应急情况下,可能会有NaCl, KCl, MgCl2 溅出。这样酸液混入料浆会随着工艺流程进入车间。在放料或跑、冒、滴、漏时,含酸的料浆就流到楼地面上,再经过构造未处理好的楼地面流到隔离层上,随着流入量的增加,酸液结晶体越来越大使楼地面被破坏,从而影响生产,楼地面变形缝构造中如果再没有处理好与楼地面的构造处理,酸液就会直接渗透楼板及大地,进而影响下面的使用空间或周边土壤及地下水。楼地面损坏的越严重,酸液流失的越多,形成恶性循环。酸液的大量流失不仅增加了生产成本、影响了生产,同时也污染了环境。
4. 防腐构造
建筑的楼面和地面是防腐蚀构造处理的重点,一般需按腐蚀类别铺设防腐蚀的隔离层、结合层及用耐酸陶瓷块材、花岗石材、水玻璃耐酸混凝土、耐碱混凝土、塑料、玻璃钢或沥青砂浆等材料铺设面层,楼地面尚须做成一定坡度并设置地沟或地漏,以便于腐蚀介质的排除和冲洗。
下面简单介绍一下黑龙江海绵钛镁电解车间楼地面的防腐构造做法。
4.1 楼地面的防腐构造。
将碎石沥青垫层放在素土夯实后的地基上(见图1),沥青混凝土垫层厚为50-300mm,并使其现浇于碎石沥青垫层上,碎石沥青垫层的厚度为150-300mm;再将耐酸砂浆找平层做在沥青混凝土垫层上(如果为楼面防腐构造时,直接将耐酸砂浆找平层做在钢筋混凝土楼面上,见图2),耐酸砂浆找平层为沥青砂浆制成,耐酸砂浆找平层要求平整;将水泥加胶结合层涂到耐酸砂浆找平层上后,立即粘贴聚异丁烯橡胶隔离层,使耐酸腐蚀板材楼地面、聚异丁烯橡胶隔离层、水泥加胶结合层和耐酸砂浆找平层形成一个整体,耐酸腐蚀板材楼地面的四周泛起200-1000mm高。
耐酸腐蚀板材是一种较好的耐酸材料,此材料与聚异丁烯橡胶绝缘层结合成一个整体。施工时耐酸腐蚀板材四周泛起高出地面,形成箱体保证酸液不会渗透到大地,有利于回收,既节约了生产成本又保护了环境。
4.2 楼面变形缝处的防腐构造。
各层施工的先后顺序:将防腐伸缩片预先埋入耐酸砂浆找平层中,耐酸砂浆找平层为沥青砂浆制成,将沥青胶泥直接灌入变形缝中,到达聚异丁烯橡胶隔离层上,灌到缝高1/3处时, 加入石棉绳,然后接着灌入沥青胶泥,这样沥青胶泥、聚异丁烯橡胶绝缘层、水泥加胶结合层和耐酸找平层形成一个整体(见图3)。
沥青胶泥也是一种较好的耐酸材料, 此材料与聚异丁烯橡胶绝缘层及耐酸腐蚀板材结合成一个整体。施工时沥青胶泥灌入变形缝中,直接于聚异丁烯橡胶绝缘层结合, 形成整体保证酸液不会渗透到钢筋混凝土楼板,有利于回收,既节约了生产成本又保护了环境。
5. 结语
在镁电解工业建筑构造设计中,防腐构造做法包括很多环节。但要做到技术先进、经济合理、坚固实用、美观大方,首先应从生产装置的工艺路线和设备布置上求得合理, 再根据厂房不同的腐蚀介质与腐蚀程度,选择合理的结构选型、正确的建筑构造措施及安全可靠的防腐材料等。另外,施工单位应严格、准确的按照防腐蚀设计构造及《工业建筑防腐蚀设计规范》的有关规定进行施工。最后防腐处理的使用年限长短也在于用户的使用与维护,所以工厂管理部门要与生产操作人员一起注重保养维修,要合理使用,保持每一项防腐工程完整无损。总之,建筑防腐处理不是一个专业能实现的,需要通过各专业、施工单位、生产及管理部门等各个环节进行相互配合、相互协调。
参考文献
[1] 朱柳,浅议工业建筑防腐控制的若干问题[J],广西城镇建设2009(5).
[2] 有色金属总公司,工业建筑的防腐蚀技术[J],化工设备与防腐蚀,1998(4).
[3] 孙立雷,浅谈工业建筑防腐设计与施工[J],山西建筑,2009年6月,第35 卷第18 期.
【关键词】镁电解车间;楼地面;防腐构造
Floor Anti-corrosion Structure of Magnesium Electrolysis Plant for Heilongjiang Titanium Sponge
Gao Yan1,Ai Chun-Zhi1,Shen li-Yuan2
(1.Shenyang Aluminium &Magnesium Engineering & Research Institute Shenyang Liaoning 110001;
2.Liaoning province building design institute for research four design Shenyang Liaoning 110001)
【Abstract】Magnesium electrolysis plant is able to be corrosive inevitably in production process. Combining with the project of magnesium electrolysis plant for Heilongjiang titanium sponge in this paper, the basic composition of magnesium electrolysis plant is introduced firstly, and the prime reason of producing corrosive for magnesium electrolysis plant is analyzed in general condition, for example, moist heat character of plant, producing corrosive gas etc. Finally, basic method of floor anti-corrosion structure for magnesium electrolysis plant is represented detailedly combining with building project design.
【Key words】Magnesium electrolysis plant;Floor;Anti-corrosion structure
1. 工程概况
黑龙江海绵钛为中外合资项目,选址位于黑龙江省佳木斯市,一期工程生产15 kt/a海绵钛。二期建设规模海绵钛的生产能力为15 kt/a,最终形成30 kt/a海绵钛的生产能力,并建设钛锭和钛板坯10 kt/a的生产能力。
2. 镁电解车间组成
镁电解车间包括:电解车间及袋滤器室、精炼及熔剂制备、氯压机室、净气室、整流所。电解槽纵向配置在厂房靠窗户的两边,操作面在厂房中间。为便于通风换气屋顶设有天窗,两边设有自然通风道。采用二层标高为5.250m操作面,直流电母线、尾气烟道、氯气导管等配置在地面上,厂房跨度30m,天车轨顶标高为13.850m。
3. 镁电解车间腐蚀产生的原因
镁电解车间厂房具有湿热特征,在生产过程中会产生侵蚀性气体如Cl2 (氯气)和HCl(氯化氢)和潮湿的导电的氯气灰尘,在应急情况下,可能会有NaCl, KCl, MgCl2 溅出。这样酸液混入料浆会随着工艺流程进入车间。在放料或跑、冒、滴、漏时,含酸的料浆就流到楼地面上,再经过构造未处理好的楼地面流到隔离层上,随着流入量的增加,酸液结晶体越来越大使楼地面被破坏,从而影响生产,楼地面变形缝构造中如果再没有处理好与楼地面的构造处理,酸液就会直接渗透楼板及大地,进而影响下面的使用空间或周边土壤及地下水。楼地面损坏的越严重,酸液流失的越多,形成恶性循环。酸液的大量流失不仅增加了生产成本、影响了生产,同时也污染了环境。
4. 防腐构造
建筑的楼面和地面是防腐蚀构造处理的重点,一般需按腐蚀类别铺设防腐蚀的隔离层、结合层及用耐酸陶瓷块材、花岗石材、水玻璃耐酸混凝土、耐碱混凝土、塑料、玻璃钢或沥青砂浆等材料铺设面层,楼地面尚须做成一定坡度并设置地沟或地漏,以便于腐蚀介质的排除和冲洗。
下面简单介绍一下黑龙江海绵钛镁电解车间楼地面的防腐构造做法。
4.1 楼地面的防腐构造。
将碎石沥青垫层放在素土夯实后的地基上(见图1),沥青混凝土垫层厚为50-300mm,并使其现浇于碎石沥青垫层上,碎石沥青垫层的厚度为150-300mm;再将耐酸砂浆找平层做在沥青混凝土垫层上(如果为楼面防腐构造时,直接将耐酸砂浆找平层做在钢筋混凝土楼面上,见图2),耐酸砂浆找平层为沥青砂浆制成,耐酸砂浆找平层要求平整;将水泥加胶结合层涂到耐酸砂浆找平层上后,立即粘贴聚异丁烯橡胶隔离层,使耐酸腐蚀板材楼地面、聚异丁烯橡胶隔离层、水泥加胶结合层和耐酸砂浆找平层形成一个整体,耐酸腐蚀板材楼地面的四周泛起200-1000mm高。
耐酸腐蚀板材是一种较好的耐酸材料,此材料与聚异丁烯橡胶绝缘层结合成一个整体。施工时耐酸腐蚀板材四周泛起高出地面,形成箱体保证酸液不会渗透到大地,有利于回收,既节约了生产成本又保护了环境。
4.2 楼面变形缝处的防腐构造。
各层施工的先后顺序:将防腐伸缩片预先埋入耐酸砂浆找平层中,耐酸砂浆找平层为沥青砂浆制成,将沥青胶泥直接灌入变形缝中,到达聚异丁烯橡胶隔离层上,灌到缝高1/3处时, 加入石棉绳,然后接着灌入沥青胶泥,这样沥青胶泥、聚异丁烯橡胶绝缘层、水泥加胶结合层和耐酸找平层形成一个整体(见图3)。
沥青胶泥也是一种较好的耐酸材料, 此材料与聚异丁烯橡胶绝缘层及耐酸腐蚀板材结合成一个整体。施工时沥青胶泥灌入变形缝中,直接于聚异丁烯橡胶绝缘层结合, 形成整体保证酸液不会渗透到钢筋混凝土楼板,有利于回收,既节约了生产成本又保护了环境。
5. 结语
在镁电解工业建筑构造设计中,防腐构造做法包括很多环节。但要做到技术先进、经济合理、坚固实用、美观大方,首先应从生产装置的工艺路线和设备布置上求得合理, 再根据厂房不同的腐蚀介质与腐蚀程度,选择合理的结构选型、正确的建筑构造措施及安全可靠的防腐材料等。另外,施工单位应严格、准确的按照防腐蚀设计构造及《工业建筑防腐蚀设计规范》的有关规定进行施工。最后防腐处理的使用年限长短也在于用户的使用与维护,所以工厂管理部门要与生产操作人员一起注重保养维修,要合理使用,保持每一项防腐工程完整无损。总之,建筑防腐处理不是一个专业能实现的,需要通过各专业、施工单位、生产及管理部门等各个环节进行相互配合、相互协调。
参考文献
[1] 朱柳,浅议工业建筑防腐控制的若干问题[J],广西城镇建设2009(5).
[2] 有色金属总公司,工业建筑的防腐蚀技术[J],化工设备与防腐蚀,1998(4).
[3] 孙立雷,浅谈工业建筑防腐设计与施工[J],山西建筑,2009年6月,第35 卷第18 期.