论文部分内容阅读
目的开展医院消毒效果监测,找出存在问题,以便改进和提高。方法对马鞍山市2009-2012年医疗机构开展环境卫生学和消毒药械效能抽样检测。结果 4年共采样1 373份,合格1 245份,平均总合格率90.68%,其中压力蒸汽灭菌器合格率为100%,无菌物品、消毒剂有效成分、室内空气、紫外线灯管和血透液合格率分别为99.11%、96.91%、96.58%、94.02%和93.18%,医务人员手、工作台面、消毒剂染菌量和专科器械合格率分别为85.66%、84.38%、82.35%和71.79%。结论马鞍山医疗机构的消毒、灭菌质量总体合格率比较高,专科器械等部分消毒效果欠佳,应重点加强监管。
Objective To carry out hospital disinfection monitoring, identify problems in order to improve and improve. Methods The medical institutions in Ma’anshan City from 2009 to 2012 to carry out environmental hygiene and disinfection drug efficiency testing. Results A total of 1 373 samples were obtained in 4 years, with a total pass rate of 1 245, with an average total pass rate of 90.68%. The qualified rate of pressure steam sterilizer was 100%. Sterile articles, active ingredients of disinfectant, indoor air, UV lamp and blood The passing rate of liquid permeation was 99.11%, 96.91%, 96.58%, 94.02% and 93.18% respectively. The passing rate of medical staff, countertops, disinfectant and special equipment were 85.66%, 84.38%, 82.35% and 71.79 %. Conclusion The overall qualified rate of disinfection and sterilization in Maanshan medical institutions is relatively high. Some disinfectants such as specialist instruments are not effective and should be supervised.