论文部分内容阅读
目的探讨凝固酶与a-葡萄糖苷酶在诊断外阴阴道假丝酵母菌病中的临床意义。方法选取鹤壁市煤业(集团)有限责任公司总医院2016年3月—2016年10月收治的5 275例门诊患者阴道分泌物样本用阴道炎五联检试剂盒(Ⅱ代)检测,同时接种念珠菌显色平板对比分析。结果阴道炎五联检试剂盒(Ⅱ代)检测假丝酵母菌的灵敏度为90.02%,特异性为93.85%,与念珠菌显色平板的符合率为92.97%,差异无统计学意义(P>0.05)。结论阴道炎五联检试剂盒(Ⅱ代)简便快速,客观准确,可以满足临床需要。
Objective To investigate the clinical significance of coagulase and a-glucosidase in the diagnosis of vulvovaginal candidiasis. Methods Vaginal secretions samples from 5 275 outpatients admitted from March 2016 to October 2016 in Hebi City General Hospital of Coal Industry (Group) Co., Ltd. Were tested in vaginal inflammation test kit (Ⅱ) and inoculated with rosary beads Comparative analysis of bacteria color plates. Results The sensitivity of Candida albicans detection kit was 90.02% and the specificity was 93.85%. The coincidence rate with Candida chromogenic plate was 92.97%, the difference was not statistically significant (P> 0.05 ). Conclusions Vaginitis five joint test kit (Ⅱ generation) is simple and rapid, objective and accurate, to meet the clinical needs.