本文给出一种测量掺Cr4+饱和吸收体基态和激发态吸收截面的方法,并用之测得国产Cr4+:YAG的两个吸收截面分别为4.3×10-18cm2和8.2×10-19cm2;同时给出一种用泵浦探测法测量可饱和吸收体μs量级基态恢复时间的方法,并用之测得国产Cr4+:YAG的基态恢复时间为3.2μ
In this paper, a method for measuring the absorption cross section of ground and excited states of Cr4 + saturated absorber is given. The measured absorption cross sections of domestic Cr4 +: YAG are 4.3 × 10-18cm2 and 8.2 × 10-19cm2 At the same time, a method of measuring the ground-state recovery time of μs order of saturable absorber by pump detection is given. The recovery time of ground state of domestic Cr4 +: YAG is 3.2μ