采用锥形量热仪对阻燃PVC壁纸的燃烧性能进行测试,并与不阻燃PVC壁纸的燃烧性能进行对比。样品质量10g,测试环境温度为22℃,相对湿度为74%。样品的底部边缘被包裹在铝箔中并水平放置在样品池中。与不阻燃PVC壁纸相比,阻燃PVC壁纸的点燃时间由5s延长至8s,燃烧时间由203s延长至234s,热释放速率峰值降低20.7%,到达热释放速率峰值的时间延长10s,热释放速率平均值可降低22.7%,热释放总量大大降低,烟释放速率降低,CO和CO2产率平均值和峰值均降低,质量损失速率的平均值和峰值较小,到达峰值的时间延长。
The pyrolysis calorimeter was used to test the flame-retardant properties of flame retardant PVC wallpaper and compared with that of non-flame retardant PVC wallpaper. Sample quality 10g, the test environment temperature is 22 ℃, relative humidity is 74%. The bottom edge of the sample is wrapped in aluminum foil and placed horizontally in the sample cell. Compared with the non-flame retardant PVC wallpaper, the ignition time of flame retardant PVC wallpaper prolonged from 5s to 8s, the combustion time extended from 203s to 234s, the peak of heat release rate decreased by 20.7%, the time to reach the peak of heat release rate extended 10s, heat release The average of the rate could be reduced by 22.7%, the total amount of heat release was greatly reduced, the rate of smoke release decreased, the average and peak values of CO and CO2 yield were decreased, the average value and peak value of mass loss rate was small, and the peak time was prolonged.