塘崖煤矿F_(10)断层是矿井深部的一条井田边界,首采区为采区东部边界断层。该断层在原勘探报告中是一条由12孔穿过的查明断层,但根据目前的井下实际资料,加上对南部357钻孔的资料分析,其原定357钻孔的部分岩芯岩石判断是错误的,F_(10)断层在原位置上应向外推。根据F_(10)断层的落差分析,F_(10)断层以西的三层煤与F_(10)断层以东的奥灰地层接近于对口接触,根据本井田的奥灰合水性,F_(10)断层也应是一条强含水断层。但根据探水钻等多种资料分析,F_(10)断层不是强含水及导水断层。
The F_ (10) fault of Tongya Coal Mine is a well field boundary in the deep mine, and the first mining area is the eastern border fault of the mining area. According to the actual downhole data and the data analysis of 357 boreholes in the southern part of the original exploration report, the fault was a confirmed fault penetrated by 12 holes. Part of the core rock of the original 357 borehole was judged as Wrong, the F_ (10) fault should be pushed outwards in the original position. According to the drop analysis of the F_ (10) fault, the three-layer coal west of the F_ (10) fault and the eastern Ordovician layer close to the F_ (10) fault are close to their counterparts. According to the O_ (10) The fault should also be a strong water cut. However, according to a variety of data such as drilling drill, F_ (10) fault is not a strong water-bearing and water-bearing fault.