Scatter correction for clinical cone-beam CT system using a stationary beam block with single scan:g

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:scutzq
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:X-ray scatter photons result in significant degradation of cone-beam CT(CBCT)image quality.Measurement based algorithms using beam block directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image.In existing algorithms,single scan and stationary beam block design proposed before is promising due to its simplicity and practicability.Although demonstrated effectively on tabletop system,the block fails to correct for the shading artifacts induced by scatter on clinical CBCT machine mainly due to inaccurate scatter estimation from gantry wobble in the scan.In this work,we investigate the motion behavior of the beam block in each projection and estimate the variation of block trajectory from the gantry wobble.An accurate scatter estimation is then achieved from the wobble modeling and high-quality images are reconstructed from the corrected projections.Methods:A "crossing-finger" shaped block was mounted on the exit of the x-ray tube of a Varian onboard imager(Fig.1&2).To estimate the gantry wobble,we track the block in equal-angular distributed projections.Then the block trajectory is estimated using the measured trajectory samples by interpolation in each projection(Fig.3).The correction of gantry wobble was implemented in scatter estimation.Scattercorrected CT images are obtained using a modified half-fan reconstruction algorithm.Results:The proposed method is evaluated using Catphan@500 phantom.Using gantry wobble estimation,our approach reduces the reconstruction error from 86 Hounsfield unit(HU)to 15 HU in the selected regions of interest(Figs.4&5),and improves the image contrast by a factor of 1.3 in the high-contrast regions(Table I).Conclusions:In this work,we propose a practical scatter correction solution with gantry wobble estimation for clinical CBCT system.The method is practical and attractive for CBCT guided radiation therapy.
其他文献
  Objective To study the intensity modulated rotary volume plan in the esophageal carcinoma radiotherapy.Methods Application of 0.6 cm3 finger ionization cham
会议
  Purpose:The most common type of cancer among women is breast cancer.Accurate assessment of skin dose in radiotherapy can provide useful information for clin
会议
  Purpose:To quantify the advantages in prescription dose escalation from helical tomotherapy(HT)compared to LINAC-based IMRT on nasopharynx cancer.Material a
会议
  Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic
会议
  Real-time monitoring of ablation effect,temperature distribution and ablated area in the tumor treatment is a core problem in microwave thermal ablation.Thr
会议
会议
  Purpose:To evaluate the impact of complexity indices on the plan quality and deliverability of the volumetric modulated arc therapy(VMAT),and to determine t
会议
  Objectives:Treatment of arterivernous malformation(AVM)of the brain is challenging due to the size and location of the nidus-proper and its proximity to the
会议
  INTRODUCTION The artifacts due to physiologic motion when using the Cartesian strategy of magnetic resonance imaging are well known [1] and many techniques
会议
  Purpose:To investigate the dosimetric characteristics of GMS BT-125-1 I-125 radioactive seed,including dose rate constant,radial dose functions and anisotro