PET/MR/CT多模式融合显像在不明原因发热中寻找致热源的价值

来源 :全军第十六届放射医学大会 | 被引量 : 0次 | 上传用户:chencm
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的:探讨18F-FDG PET/MR/CT显像在不明原因发热(fever of unknown origin,FUO)中的诊断价值. 方法:对在2009年至2014年间符合不明原因发热诊断标准的57病例,行18F-FDG PET/MR/CT显像,通过目测法和半定量分析方法对18F-FDG PET/MR/CT的诊断结果进行评价. 结果:57例不明原因发热患者,全部行PET/MR或PET/CT检查后通过手术探查或穿刺活检获得病理诊断,临床诊断而非手术治疗者随访半年以上,其中能明确找到致热源的有43例,包括感染性炎性反应16例,恶性肿瘤12例,非感染性炎性反应8例,其他类型7例,未能发现病因14例.而18F-FDG PET/MR/CT显像诊断真阳性38例,假阳性5例,假阴性3例,真阴性11例.18F-FDG PET/MR/CT的灵敏度93.5%,特异性73.7%;阳性预测值88.4%,阴性预测值78.6%. 结论:18F-FDG PET/MR/CT显像在临床"不明原因发热"的诊疗中具有独特价值.
其他文献
Objective: To explore the clinical application value of dual-energy imaging with Dual-source CT(2008G Siemens Somatom Definition) for head and cervical vessel diseases.Methods: The imaging data underw
Objective To show the improved diagnostic image quality of dual-energy myocardial scan mode compared with coronary CTA scan mode with Dual-Source CT.Methods We performed a retrospective analysis of 10
Objective To investigate the clinical value and accuracy of DSCT in the assessment of the pulmonary arteries in patients with complex congenital heart disease.Materitals and methods DSCT and echocardi
Purpose: To investigate the accuracy of right ventricular function in patients with Tetralogy of Fallot(TOF) by two methods(by MPR and VR methods) by DSCT.Methods and Materials: 30 patients underwent
会议
Purpose: To evaluate the right ventricular time-volume curves in patients with Tetralogy of Fallot.Methods and Materials: Retrospectively analyze right ventricular time-volume of 18 TOF and 4 healthy
会议
Objective The purpose of this study is to evaluate the prevalence and characteristics of myocardial bridging (MB) in a large series of patients and to assess the relationship between atherosclerosis a
Objective To evaluate the diagnostic value of dual source CT coronary angiography in patients with congenital coronary artery anomalies(CCAA).Methods The 1350 patients data of DSCT coronary angiograph
Objective To explore the clinical value of dual-source CT in diagnosis of congenital heart diseases.Methods 68 cases of congenital heart disease which were comfirmed by surgery were collected,includin
urpose: To investigate the diagnostic value of dual-source CT perfusion imaging(CTPI)features in hepatiocellular carcinoma(HCC) , hepatic hemangiom and Focal nodular hyperplasia(FNH).and to determine
Objective To evaluate the effect of dual source CT (DSCT) on left ventricle volume and function of pigs after close myocardial contusion, and make a comparison with the result before and after close m