Evaluation of Dose Verification of Anisotropic Analytical Algorithm and Pencil Beam Convolution for

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:weilanqq
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective To compare the dosimetric difference between anisotropic analytical algorithm(AAA)and pencil beam convolution(PBC)for intensity modulated radiation therapy(IMRT)Plans in esophageal carcioma.Methods For nine esophageal cancer cases,IMRT plan(five fixed-fields),which calculated with AAA and PBC,were generated by Varian Eclipse 8.6 treatment planning systerm.The COMPASS dose verification system was used to verify these plans.The difference of dose distribution to target and organs at risk(OAR)was compared.Results The gamma pass rates of GTV,PTV,lung and heart in AAA were higher than PBC(P<0.05).There were significant differences in Dmean、V100%、HI of GTV,and there were only significant differences in HI of PTV.AAA had more advantages.The two algorithm in double lung index between the difference was significant differences.But,the difference of AAA was smaller.The differences of heart`s Dmean,V30,V40 in two algorithm were similar(P>0.05).The D01 of spinal cord in planned value is higher than the measured value,the difference was 1.56±0.25%for AAA and 4.48±1.13%for PBC.Conclusion Esophageal carcioma radiotherapy using the AAA algorithm is more accurate than using the PBC algorithm.
其他文献
  Purpose:To Time-of-Flight positron emission tomography(TOF-PET),the TOF benefit highly depends on the system timing precision.As a result,it is meaningful t
会议
  Objective:To investigate the scatter factor of Irdium192 HDR source during calibration in air.Methods:All measurements are performed with thimble 0.6cc Farm
会议
  Purpose:To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans.Methods:For prostate SBRT cases,rec
会议
  Purpose:Development of MR/CT compatible and tissue-equivalent phantom was proposed for MRI-only based radiotherapy.Materials and Methods:The MR/CT compatibl
会议
  Purpose:Many accidents could happen during treatment planning in radiotherapy.Data mining and machine learning techniques could be powerful tools for medica
会议
  Purpose:To explore the effects of changes in the gross tumor volume(GTV)on dose distribution in organs at risk(OARs)and healthy brain tissue in patients wit
会议
  Purpose:To effectively manage tumor motion in pancreas treatment using MR guided radiotherapy,automated segmentation needs to be performed.A low rank decomp
会议
  Purpose:The accuracy of deformable image registration(DIR)algorithms could have a significant impact on treatment planning,especially for adaptive radiother
会议
会议
  Purpose:The purpose of this study was to test feasibility of clinical usage of flattening filter free(FFF)beam for treatment of lung stereotactic ablative r
会议