New Time Resolution Measurement Method

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:honglei413413
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To Time-of-Flight positron emission tomography(TOF-PET),the TOF benefit highly depends on the system timing precision.As a result,it is meaningful to measure the time resolution of the PET system.However,there is not any standard procedure for the measurement.In the article,we used the standard NEMA NECR and NEMA sensitivity coincidence data to analyze the PET system time resolution.Methods:The NECR measurement has many scatter events during the PET scanning.It is difficult to distinguish the real events and the scatters events.It is hard to evaluate the scatter events as well.Therefore,we proposed to use the coincidence data acquired from standard NEMA sensitivity measurement procedure.We used at least 10000 trues per slice collected from the sensitivity data acquired by the PET system.It is hard to ignore the statistics error on each Line-of-Response(LOR).It is necessary to merge the data of all five data sets acquired with different size absorbers.In practice,Inaccurate positioning of the line source in the center of PET FOV may lead to imprecise time resolution result.In order to compensate the time difference caused by misplacing,we introduced a source alignment procedure,which takes the advantage of the rigid line source.ResultsBy using the proposed method,we can get a global time resolution measurement.Conclusions:It is shown that,by using the sensitivity data acquired by standard NEMA procedure,we can get a measurement of the time resolution of the PET system.
其他文献
  Purpose:The most common type of cancer among women is breast cancer.Accurate assessment of skin dose in radiotherapy can provide useful information for clin
会议
  Purpose:To quantify the advantages in prescription dose escalation from helical tomotherapy(HT)compared to LINAC-based IMRT on nasopharynx cancer.Material a
会议
  Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic
会议
  Real-time monitoring of ablation effect,temperature distribution and ablated area in the tumor treatment is a core problem in microwave thermal ablation.Thr
会议
会议
  Purpose:To evaluate the impact of complexity indices on the plan quality and deliverability of the volumetric modulated arc therapy(VMAT),and to determine t
会议
  Objectives:Treatment of arterivernous malformation(AVM)of the brain is challenging due to the size and location of the nidus-proper and its proximity to the
会议
  INTRODUCTION The artifacts due to physiologic motion when using the Cartesian strategy of magnetic resonance imaging are well known [1] and many techniques
会议
  Purpose:To investigate the dosimetric characteristics of GMS BT-125-1 I-125 radioactive seed,including dose rate constant,radial dose functions and anisotro
会议
  Purpose:X-ray scatter photons result in significant degradation of cone-beam CT(CBCT)image quality.Measurement based algorithms using beam block directly ac
会议