The scatter factor of the afterloading Irdium192 source calibration in air

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:jealy0717
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective:To investigate the scatter factor of Irdium192 HDR source during calibration in air.Methods:All measurements are performed with thimble 0.6cc Farmer type thimble chamber and PTW well-type chamber.The well type chamber has been placed 1 metre above the floor to guarantee negligible influence of the floor scattering.The distance of outer lateral surface of the chamber to room wall was varied in the range 5cm to 200cm.The sensitivity of the well-type chamber for scattering from room wall on different distance was investigated and then the reading at each distance has been normalized to the response for 200cm distance.The Ir192 source and thimble chamber with build-up cap were positioned on the mobile stand and the distance between the source and chamber(SCD)was varied accurately from 5cm~40cm during the calibration.In the calibration procedure,the air Kerma has been measured according the multiple distance method(Goetsch)、DGMP and shadow field method(SF)at several different distances from the center of the active core of the source and the reference point of the ionization chamber in a specially designed jig.During shadow field method(SF)the seven distances measurement is taken in two phases,the first phases is the measurement without shield,the second one with a 6cm(three-tenth value layer)cone of lead block placed as close as possible the source and fully shield the chamber.Data was analyzed and fitted with Origin 8.0 software.All correction such as leakage、end-effect and chamber gradient are required prior to measurement.Results:For calibration with well type chamber the scatter is less influence from 1 meter distance from the lateral wall of the room.The result also shows that with Goetsch and DGMP method the scatter factor is independent of SCD and negligible.With the Shadow Field method the scatter factor is less but constant basically.conclusion:The calibration have to carry out in minimum scatter environment with well type chamber at least 1 meter away from any wall or floor.For calibration in air with thimble chamber it is best to measurement the scatter in local and the SF likely will serve the better method of obtaining a scatter factor.
其他文献
  Purpose:To quantify the advantages in prescription dose escalation from helical tomotherapy(HT)compared to LINAC-based IMRT on nasopharynx cancer.Material a
会议
  Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic
会议
  Real-time monitoring of ablation effect,temperature distribution and ablated area in the tumor treatment is a core problem in microwave thermal ablation.Thr
会议
会议
  Purpose:To evaluate the impact of complexity indices on the plan quality and deliverability of the volumetric modulated arc therapy(VMAT),and to determine t
会议
  Objectives:Treatment of arterivernous malformation(AVM)of the brain is challenging due to the size and location of the nidus-proper and its proximity to the
会议
  INTRODUCTION The artifacts due to physiologic motion when using the Cartesian strategy of magnetic resonance imaging are well known [1] and many techniques
会议
  Purpose:To investigate the dosimetric characteristics of GMS BT-125-1 I-125 radioactive seed,including dose rate constant,radial dose functions and anisotro
会议
  Purpose:X-ray scatter photons result in significant degradation of cone-beam CT(CBCT)image quality.Measurement based algorithms using beam block directly ac
会议
  Purpose:To Time-of-Flight positron emission tomography(TOF-PET),the TOF benefit highly depends on the system timing precision.As a result,it is meaningful t
会议