锅炉在运行中,因缺水、满水而造成的事故大约占整个锅炉事故的70%。而因人为的水上事故约占整个事故的50%左右。所以国家劳动总局根据大量事实,颁发了《蒸汽锅炉安全监察规程》。规程第108条规定,蒸发量2吨/时的锅炉,必须装设高低水位警报器,且报警信号能区分高低水位。第117条规定,蒸发量>4吨/时的锅炉,应装置自动进水调节器。由于管理不善,我厂四台 SZP6.5—13锅炉一直没有装设上述两种装置。司炉操作中,只凭眼睛
Boiler operation, due to lack of water, full of water caused the accident about 70% of the entire boiler accident. The man-made water accident accounts for about 50% of the total accident. Therefore, the State Administration of labor based on a large number of facts, issued a “steam boiler safety supervision regulations.” Article 108 of the Regulation stipulates that boilers with an evaporation of 2 tons / hour shall be fitted with high and low water level sounders, and the alarm signal can distinguish between high and low water levels. Article 117 stipulates that boilers with evaporation> 4 t / h should be fitted with automatic water regulators. Due to poor management, I plant four SZP6.5-13 boiler has not installed the above two devices. Stove operation, eyes only