论文部分内容阅读
Purpose:Subtrochanteric fractures of the femur are being managed successfully with various intramedullary and extramedulary implants with reasonable success.However,these implants require precise placement under image intensifier guidance,which exposes the surgeon to substantial amount of radiation.It also restricts the management of these fractures at peripheral centers where facility of image intensifiers is not available.Keeping this in mind we designed this study to identify if contralateral reversed distal femoral locking plate can be used successfully without the use of image intensifier.Methods:Twenty-four consecutive patients (18 men and 6 women) with a mean age of 28 years (range 19-47 years) suffering subtrochanteric fractures of the femur underwent open reduction and intal fixation with reversed contralateral distal femoral locking plate.The outcome was assessed at the mean follow-up period of 3.2 years (range 2-4.6 years) using the Harris hip score.Results:Twenty-one fractures united with the primary procedure,with a mean time of consolidation being 11 weeks (range,9-16 weeks).One patient developed superficial suture line infection,which resolved with oral antibiotics.Another patient had a fall 3 weeks after surgery and broke the plate.Repeat surgery with reversed distal femoral locking compression plate was performed along with bone grafting and the fracture united.Two cases had nonunion,which went in for union after bone grafting.The mean Harris hip score at the time of final follow-up was 90.63 (range 82-97).Conclusion:The reversed contralateral distal femoral plate is a biomechanically sound implant,which when used for fixation of the subtrochanteric fractures with minimal soft tissue stripping shows results comparable to those achieved by using other extramedullary implants as well as intramedullary devices.The added advantage of this implant is its usability in the absence of an image intensifier.