论文部分内容阅读
目的了解泰安市医疗机构消毒灭菌质量,找出存在的问题,以便加强消毒管理。方法通过现场抽样检测方法,对辖区内各级医疗机构消毒与灭菌质量进行监测。结果 2014年从46家医疗机构中共采样608份,平均合格率为81.25%。不同监测项目中,使用中消毒剂、无菌物品和压力蒸汽灭菌器监测全部合格,诊疗用水合格率仅为32.63%。不同类型医疗机构消毒质量差异无规律,总体上省市级医院合格率略高,乡镇卫生院偏低。结论泰安市医疗机构消毒质量总体不高,但无菌物品和压力蒸汽灭菌监测全部合格,应加强薄弱项目消毒管理。
Objective To understand the quality of disinfection and sterilization in medical institutions in Tai’an and to find out the existing problems in order to strengthen the disinfection and management. Methods By means of on-site sampling and testing, the quality of disinfection and sterilization of medical institutions at all levels in the area was monitored. Results A total of 608 samples were taken from 46 medical institutions in 2014, with an average passing rate of 81.25%. Among the different monitoring items, all disinfectants, sterilized articles and pressure steam sterilizer were used for monitoring. The passing rate of diagnosis and treatment water was only 32.63%. Different types of medical institutions, there is no difference in the quality of disinfection, the general provincial and provincial hospitals a slightly higher pass rate, lower township hospitals. Conclusion The disinfection quality of medical institutions in Tai’an is generally not high, but all sterilized articles and pressure steam sterilization monitoring should be qualified, and the disinfection management of weak items should be strengthened.