论文部分内容阅读
通过结合某电厂工程实例,对大、中型冷却塔水池池壁产生的裂缝进行技术分析,从设计和施工两方面提出了控制冷却塔池壁产生裂缝的措施,并在工程中进行了验证,对以后冷却塔池壁控制裂缝的产生具有一定的借鉴意义。
By combining a power plant project example, the technical analysis of the cracks in the pool wall of large and medium-sized cooling tower pools was made. The measures to control the cracks in the cooling tower wall were put forward from the aspects of design and construction, and verified in the project. After cooling tower wall cracks have a certain reference significance.