兰郑长成品油管道庆咸支线投产后,首末站采用超声波流量计测量数据进行管容计算,得到的柴油和汽油的测量结果与实际管容存在较大的误差。从超声波流量计的测量原理入手,分析发现影响测量准确性的主要因素是雷诺数,其主要由油品的性质、温度以及油品流速决定,由此计算获得在相同测量条件下,柴油、汽油理论测量误差范围约为5%~6%,与实际运行测量误差相近,从理论上解释了产生测量偏差的原因。结合庆咸支线超声波流量计实测数据,提出了解决测量误差的方案,提高了油品批次界面跟踪预测的准确性。
Lan Cheng Chang Cheng oil pipeline Qingyan Extension put into operation, the first and last stations using ultrasonic flowmeter measurement data pipe capacity calculation, the measured diesel and gasoline measurement results and the actual pipe capacity there is a big error. Starting from the measuring principle of the ultrasonic flowmeter, the main factors that influence the accuracy of the measurement are the Reynolds number, which is mainly determined by the nature of the oil, the temperature and the flow rate of the oil, so that under the same measuring conditions, the diesel, gasoline Theoretical measurement error range of about 5% to 6%, and the actual operation of the measurement error is similar to the theoretical explanation of the reasons for the measurement error. Combined with the measured data of Qingyan Branchline Ultrasonic Flowmeter, a scheme to solve the measurement error is put forward, which improves the accuracy of tracking and predicting the oil batch interface.