论文部分内容阅读
CARR中子织构衍射仪在2011年完成了多个关键部件的设计、安装、调试,主要包括准直系统、单色系统、限束系统,同时对探测器屏蔽体和谱仪测控软件进行了改造。准直系统包括准直器和姿态调整装置。准直器用来对中子束发散度进行限制,而姿态调整装置则用来对准直器进行姿态微调。第一准直器姿态调整装置在设计时考虑了不同发散度准直器的选择
CARR neutron textured diffractometer completed the design, installation and commissioning of several key components in 2011, mainly including the collimation system, monochromatic system and beam limiting system. At the same time, the detector shield and spectrometer measurement and control software Transformation. Alignment system includes collimator and attitude adjustment device. The collimator is used to limit the divergence of the neutron beam, and the attitude adjusting device is used to finely adjust the attitude of the collimator. The first collimator attitude adjustment device takes into account the choice of different divergence collimators in the design