一、概述按照CNAS-CL07:2011《测量不确定度要求》的要求,一般情况下,报告校准结果时,应同时给出相应的测量不确定度,特别是当被测量的值是一个范围时,其校准和测量能力(CMC)的表示必须覆盖被测量范围的每一个量值。为满足这一要求,本文以质量比较仪XP205为例,依据JJF1326-2011《质量比较仪校准规范》,借助Excel电子表格,计算质量比较仪XP205在0~200g范围内所有测量点的扩展不确定度。并用CNAS-CL07:2011提出的CMC的5种表示方式分别表示测试结果。
I. Overview According to the requirements of CNAS-CL07: 2011 “Measurement Uncertainty Requirements”, under normal circumstances, when reporting the calibration results, corresponding measurement uncertainty should be given at the same time, especially when the measured value is within a range , The calibration and measurement capability (CMC) representation must cover each of the measured ranges. In order to meet this requirement, in this paper, the quality comparator XP205, for example, according to JJF1326-2011 “quality comparator calibration specification”, with Excel spreadsheet, calculate the quality comparator XP205 in the 0 ~ 200g range of all measurement points of the expansion of uncertainty degree. And with CNAS-CL07: 2011 proposed five kinds of CMC represent the test results.