论文部分内容阅读
【摘 要】 针对当前排水检测行业中部分水质检测指标如化学需氧量、悬浮物、石油类、总砷、总汞、大肠菌群等存在操作繁琐、需要消耗较多化学试剂、检出限较高等问题,根据工作实际逐一加以改进和优化。改进后的方法具有操作简便、快速、污染少、准确度高等特点,可广泛应用于环境监测、排水检测等行业的日常检测工作中。
【关键词】 排水检测;水质;检测方法;优化;改进
Optimization and Improvement of some Water Quality Detection Methods in the Drainage Monitoring System
Zan Lujun
Xi’an Urban Drainage Monitoring Station, Xi’an 710016, Shaanxi,China
【Abstract】 At present there are still many problems of complex operation, demanding of many reagents and high detection limits of some water quality detection methods in the drainage monitoring system, such as the factors of chemical oxygen demand, suspended solids, petroleum oils, total arsenic, total mercury, and coliform bacteria. The optimized and improved methods were discussed in this work. The proposed methods have the special features of simple in operation, fast analytical speed, less pollution and high accuracy, and can be widely used for the routine analysis of environmental monitoring and drainage detection.
【Key Words】 drainage monitoring; water quality; detection methods; optimization; improvement.
目前,城市排水检测行业中水样的检测方法,主要采用國家和行业两类标准。对于国家标准,包括早期的由国家质检总局发布的和近几年开始由环保部发布的标准:1999年(含)以后的水质标准主要由环境保护部发布,标准号不再采用“GB(/T)××××(×)(标准号)-××(标准发布年的最后2位)”,而是以环保行业标准代替国家标准,即“HJ(/T)××××(×)(标准号)-××××(标准发布年)”。部分水质检测指标由于缺少国家标准,如溶解性固体、易沉固体等,则采用《城市污水水质检验方法标准》(CJ/T51-2004)。
随着检测技术的不断发展,新的检测仪器设备的不断推出,加上标准修订和更新的滞后,许多检测标准中规定的操作方法在实际检测工作中难免会出现一些问题,如操作繁琐,使用大量化学试剂(包括毒性较高的试剂),检出限较高,甚至标准本身还存在一些错误等。受制于国内部分标准的发布年限比较久,并且标准的修订是一个比较复杂的系统工程,短期内难以及时更新与完善。因此,在实际工作中,对这些存在问题的检测标准,检测机构可以参照当前国际或者同行研究的先进方法,根据实际情况加以优化和改进,从而达到提高检测工作质量和效率的目的。
1、化学需氧量(CODcr)
化学需氧量作为国家及环保行业重点控制的排污指标之一,在《污水综合排放标准》、《城镇污
水处理厂污染物排放标准》、《地表水环境质量标准》及《污水排入城镇下水道水质标准》等国家、行业标准中均规定了最高允许排放浓度。实验室中对化学需氧量的检测,主要采用两种检测方法:重铬酸盐法及快速消解分光光度法。前者属于传统的容量滴定法,后者则采用分光光度法。两种方法的原理都是基于在强酸、加热条件下,采用重铬酸钾作为氧化剂时,水样中溶解性物质及悬浮物所消耗的重铬酸盐所对应的氧的质量浓度。
快速消解分光光度法虽然只消耗较少的消解试剂—重铬酸钾,对环境造成的污染较小,但是由
于该方法取样量较少,并且需要绘制工作曲线,因此,在实际检测中,其检测结果的准确性仍需要与经典方法进行比对。这里只讨论对重铬酸盐法的优化与改进。
1.1存在的问题
重铬酸盐法需要使用高功率(每一联电炉的功率一般为1KW)的电炉进行蒸馏,并使用水进
行循环冷却2-3小时。缺点显而易见:加热装置功率过大,实验室普遍采用的六联电炉功率为6KW,大大超过了常规电源插座的额定功率;回流过程需要保持冷凝水不间断开启2-3小时,造成资源的浪费;连接冷凝管的橡胶管在高温下容易老化,从而导致破损漏水,发生安全事故。
1.2优化和改进的方法
针对加热和回流中出现的问题,可采用已经商品化自动加热回流装置。该套装置中,加热部分改为电热板,最大功率仅为1.5KW左右;回流冷凝部分则采用风冷降温,只需使用少量的冷凝水(每管不多于100mL水),借助仪器内部风扇进行冷却;各个冷凝管独自连接,不需橡胶管串联;此外,加热时间可由仪器自动控制。这样,加热回流过程中所使用的电、水都大大节省,并且安全性提高不少。
2、悬浮物(SS)
2.1存在的问题
【关键词】 排水检测;水质;检测方法;优化;改进
Optimization and Improvement of some Water Quality Detection Methods in the Drainage Monitoring System
Zan Lujun
Xi’an Urban Drainage Monitoring Station, Xi’an 710016, Shaanxi,China
【Abstract】 At present there are still many problems of complex operation, demanding of many reagents and high detection limits of some water quality detection methods in the drainage monitoring system, such as the factors of chemical oxygen demand, suspended solids, petroleum oils, total arsenic, total mercury, and coliform bacteria. The optimized and improved methods were discussed in this work. The proposed methods have the special features of simple in operation, fast analytical speed, less pollution and high accuracy, and can be widely used for the routine analysis of environmental monitoring and drainage detection.
【Key Words】 drainage monitoring; water quality; detection methods; optimization; improvement.
目前,城市排水检测行业中水样的检测方法,主要采用國家和行业两类标准。对于国家标准,包括早期的由国家质检总局发布的和近几年开始由环保部发布的标准:1999年(含)以后的水质标准主要由环境保护部发布,标准号不再采用“GB(/T)××××(×)(标准号)-××(标准发布年的最后2位)”,而是以环保行业标准代替国家标准,即“HJ(/T)××××(×)(标准号)-××××(标准发布年)”。部分水质检测指标由于缺少国家标准,如溶解性固体、易沉固体等,则采用《城市污水水质检验方法标准》(CJ/T51-2004)。
随着检测技术的不断发展,新的检测仪器设备的不断推出,加上标准修订和更新的滞后,许多检测标准中规定的操作方法在实际检测工作中难免会出现一些问题,如操作繁琐,使用大量化学试剂(包括毒性较高的试剂),检出限较高,甚至标准本身还存在一些错误等。受制于国内部分标准的发布年限比较久,并且标准的修订是一个比较复杂的系统工程,短期内难以及时更新与完善。因此,在实际工作中,对这些存在问题的检测标准,检测机构可以参照当前国际或者同行研究的先进方法,根据实际情况加以优化和改进,从而达到提高检测工作质量和效率的目的。
1、化学需氧量(CODcr)
化学需氧量作为国家及环保行业重点控制的排污指标之一,在《污水综合排放标准》、《城镇污
水处理厂污染物排放标准》、《地表水环境质量标准》及《污水排入城镇下水道水质标准》等国家、行业标准中均规定了最高允许排放浓度。实验室中对化学需氧量的检测,主要采用两种检测方法:重铬酸盐法及快速消解分光光度法。前者属于传统的容量滴定法,后者则采用分光光度法。两种方法的原理都是基于在强酸、加热条件下,采用重铬酸钾作为氧化剂时,水样中溶解性物质及悬浮物所消耗的重铬酸盐所对应的氧的质量浓度。
快速消解分光光度法虽然只消耗较少的消解试剂—重铬酸钾,对环境造成的污染较小,但是由
于该方法取样量较少,并且需要绘制工作曲线,因此,在实际检测中,其检测结果的准确性仍需要与经典方法进行比对。这里只讨论对重铬酸盐法的优化与改进。
1.1存在的问题
重铬酸盐法需要使用高功率(每一联电炉的功率一般为1KW)的电炉进行蒸馏,并使用水进
行循环冷却2-3小时。缺点显而易见:加热装置功率过大,实验室普遍采用的六联电炉功率为6KW,大大超过了常规电源插座的额定功率;回流过程需要保持冷凝水不间断开启2-3小时,造成资源的浪费;连接冷凝管的橡胶管在高温下容易老化,从而导致破损漏水,发生安全事故。
1.2优化和改进的方法
针对加热和回流中出现的问题,可采用已经商品化自动加热回流装置。该套装置中,加热部分改为电热板,最大功率仅为1.5KW左右;回流冷凝部分则采用风冷降温,只需使用少量的冷凝水(每管不多于100mL水),借助仪器内部风扇进行冷却;各个冷凝管独自连接,不需橡胶管串联;此外,加热时间可由仪器自动控制。这样,加热回流过程中所使用的电、水都大大节省,并且安全性提高不少。
2、悬浮物(SS)
2.1存在的问题